7

 
F.

 

Display: Backlit, Blue Background, 2 lines with 20 characters on each line. 

G.

 

Keypad: Full travel keys with elastomeric contact pad, 4 rows x 4 columns. 

H.

 

Serial Port: RS-232 using 6 position (4 contact) RJ-11 modular connection. 

I.

 

Serial Port: RS-485 (Local Area Network) using RJ-11 modular connection. 

J.

 

Parallel port: 25-pin DB connection. 

K.

 

Internal 56K Modem, licensed for use over public telephone lines. 

L.

 

Internal Multi-Frequency Piezo Electric Buzzer. 

M.

 

Internal Barcode Reader: Visible or Infrared Barcode reading through the slot. 

N.

 

Control lines: Two pins of the 6-pin circular DIN connector can be used with 
external relay box to control devices such as door locks and bells. 

O.

 

External Barcode port: 6-pin DIN connection for external Barcode Wand or 
Barcode Gun. 

P.

 

Power: Wall mount transformer, 9 Volts AC 1 amp standard or 3 amp for units 
with FIU, Modem or Wireless communications. 

Q.

 

Fingerprint: CCD Technology. 

R.

 

Proximity: 125kHz RFID Proximity Reader or HID Proximity Reader. 

S.

 

Ethernet: 10/100 baseT Ethernet Interface. 

T.

 

Wireless 10 baseT 802.11b wireless communications. 

U.

 

Flash program storage. 

V.

 

State of the Art FRAM Data Storage. 

 
 
 
 
 
 
 
 

 

Summary of Contents for Data Collection Terminal DC7000

Page 1: ...DC7000 Data Collection Terminal Hardware Manual ...

Page 2: ... jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA A compliant telephone cord and modular plug is provided with this product It is designed to be connected to a compatible modular jack that is also compliant See installation instructions for details The REN is used to determine the...

Page 3: ...onnected to the telephone line ensure the installation of this 4G3MM00B1011 does not disable your alarm equipment If you have questions about what will disable alarm equipment consult your telephone company or a qualified installer Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numerique de la classe A est conforme a la norme NMB 003 Du Canada Lithium Battery Ca...

Page 4: ... equipment to which this declaration relates are in conformity with the following standards EN61000 6 1 EN55022 1998 with Amendment A1 2000 CISPR 22 I the undersigned hereby declare that the equipment specified above conforms to the above directive and standards Raleigh North Carolina USA May 22 2006 W Glenn Robbins All Rights Reserved COPYRIGHT 2006 Acroprint Time Recorder Company ...

Page 5: ...Ethernet Port 12 Wireless WiFi Connection 13 RS 232 Serial Port 13 RS 232 Cabling 14 Local Area Network RS 485 Serial Port 15 RS 485 Serial Cables 16 Modem Port 17 Modem Cables 18 Wand Port 19 Wand and Y Cable 20 Parallel Port 21 Parallel Cable 22 5 Companion Products 23 Readers 23 Power Supplies 23 External Relay Box External Buzzer 24 Cables 25 Cables Converter Badge Racks 26 6 Appendix 27 Acrop...

Page 6: ...s as listed below Comm2 RS485 MODEM Ethernet or wireless Ethernet Barcode Internal Visible or Infrared Barcode Badge Reader Proximity Proximity badge reader 125kHz RFID or HID Fingerprint Fingerprint Verification Magnetic Stripe A Track 2 ABA magnetic badge reader is standard but can be optioned out Note The part number of your unit can be found on the serial number label on the back of the termin...

Page 7: ...ode Reader Visible or Infrared Barcode reading through the slot N Control lines Two pins of the 6 pin circular DIN connector can be used with external relay box to control devices such as door locks and bells O External Barcode port 6 pin DIN connection for external Barcode Wand or Barcode Gun P Power Wall mount transformer 9 Volts AC 1 amp standard or 3 amp for units with FIU Modem or Wireless co...

Page 8: ...H non condensing areas of high dust concentration areas with chemical fume concentration areas with extreme vibration or when placed on an unstable or unlevel surface Unpacking and Inspection Open the shipping carton and carefully remove the contents Inspect the terminal and accessories for damage Report damage or shortages to the company from which the unit was purchased Complete the registration...

Page 9: ...lied by a Listed Direct Plug in Power Unit marked Class 2 or LPS Rated 9v to 12v DC 1000mA to 3000mA Plug in the power cord coming from the wall mount transformer into the terminal To reattach the access door and secure the unit to the reversible bracket screw on the door NOTE Other connections are made in the same fashion Notice the channels in the bracket available for cable routing Also the bra...

Page 10: ...10 3 Operator Interface Keypads The standard terminal keypad has 16 keys for entering alphabetical and numeric data as illustrated below Standard Alpha Numeric Keypad MENU MENU Optional Numeric Keypad ...

Page 11: ...le barcode readers are available The card is swiped through in the same fashion but the barcode should be on the left side of the card when swiped NOTE For through the slot reading the barcode should be located on card as shown Available barcode symbologies are 3 of 9 Code 39 and 2 of 5 Interleaved Barcode Print Contrast Signal 70 Min 1 00 Min Quiet Zones 0 35 Min 4 Barcode Resolution 01 10mil Min...

Page 12: ...Read Only H10301 Std 26 Bit Facility Code 101 Note the reader is not restricted to 26 Bit badges 4 Ports and Connections Ethernet Port The Ethernet port is located on the lower left corner of the terminal It is a 10 position 8 pin female port which will accept a male 10 100BASE T RJ 45 modular connector The terminal has the capability to communicate across an intranet a WAN or the Internet Etherne...

Page 13: ...ial port is located on the lower left corner of the terminal It is a six position 4 pin female port which will accept a male RJ 11 modular connector The DC7000 Terminal can use RS 232 serial communication to connect directly to a host computer A connection for an IBM PC or IBM PC compatible computer is shown on the following page ...

Page 14: ...rom END VIEW as viewed from the outside of the connectors Schematic Schematic Use DB 25 RS 232 Host Cable Assy See pp 24 25 Cabling to Host Computer with DB 9 Port Schematic DB 9 to RJ 11 Adaptor Adaptor A Standard Modular Cable DB 25 to RJ 11 Adaptor Adaptor A NOTE Schematic connections are shown from END VIEW as viewed from the outside of the connectors Schematic ...

Page 15: ...s typically used in conjunction with an RS 232 RS 485 converter to complete the connection Through software the host can communicate with individual terminals even though they are wired in parallel RS 485 communication uses a differential bus which provides good protection from interference over long runs of up to 4000 feet NOTE When wiring a network always follow the electric wiring codes in your...

Page 16: ...ted to one serial port An RS232 port on the host PC is used with an RS232 RS485 converter to complete the connection B B RS485 provides good protection from interference over long runs up to 4000 ft Note When wiring a network always follow the electric wiring codes in your area Typically a Teflon coated wire is required for wiring through a ceiling The junction box to junction box wire shown is a ...

Page 17: ... will not have an Ethernet or RS 485 port The Modem Port is a 6 position 4 pin female port which will accept a male RJ 11 modular connector The internal modem modulator demodulator converts electronic data into tones which are then transmitted over phone lines Warning Connecting to a digital phone system will damage the modem and void the warranty ...

Page 18: ...e RJ 11 jack for tip and ring Connect one end of the cable to the terminal and plug the other end into your RJ 11 type modular telephone wall jack The RJ 11 wall jack should be of the analog telephone type and not a digital network jack Warning Connecting to a digital phone system will damage the modem and void the warranty If a modular wall jack is not available obtain an adaptor from your local ...

Page 19: ...ode Gun non contact reader is used the center pin supplies additional power The terminal uses 2 of the remaining pins as logic lines for external controls See pin out and function table below Pin Function 1 5 Volts 2 Signal Control Logic Line Digital IO 0 Output Only 3 Barcode Wand Receive Data 4 Ground 5 Access Logic Line Digital IO 1 Output Only 6 12 Volt Unregulated Maximum current draw 220 mA ...

Page 20: ...label Check the software manual to identify the codes your terminal will read The Y cable shown below allows for connection of both a wand and other external devices The single end of the cable is plugged into the terminal A wand can be connected to one split and another device to the other See appendix for External Relay Box part number Y cable splitter Barcode Wand ...

Page 21: ...ich will accept a 25 pin male connector This type of parallel port is typically used on IBM PC or IBM PC compatible computers The DC7000 terminal provides strain relief if the connector is locked in by the securing screws Securing the parallel cable to the wall or mounting surface can obtain additional strain relief ...

Page 22: ...Since this is the same cable that is used to connect an IBM PC or compatible to a printer it will likely be available from most computer dealers off the shelf One end is a male DB 25 connector the other end is a 36 pin Centronics type connector to match the parallel port on the printer Note Schematic connections are shown from END VIEW As viewed from the outside of the connectors Parallel Cable Sc...

Page 23: ...0VAC to 9VAC 1A 56 0113 000 Power Supply 120 240VAC to 12VAC 3A 56 0128 000 Power Supply Required for Terminals with Fingerprint Reader Modem or Wireless Communication Note Comes with Std 2 Blade US Plug 75 0166 000 Optional Available Adaptors Continental Europe 75 0167 000 U K Ireland 75 0168 000 Australia New Zealand 75 0169 000 S Africa India 75 0170 000 ...

Page 24: ...24 External Relay Box External Buzzer External Relay Box 120 V 01 0121 000 External Buzzer 01 0122 000 ...

Page 25: ...RS 232 Host Cable Assembly Includes DB 25 Female RS 232 host to RJ 11 Female adaptor and Standard Modular Cable length 7 feet 25 0116 000 50 feet 25 0116 007 DB 9 RS 232 Host Cable Assembly Includes DB 9 RS 232 host to RJ 11 female adaptor and Standard Modular Cable length 7 feet 25 0116 004 50 feet 25 0116 008 9 Pin RS 232 to USB Adaptor 63 0181 001 ...

Page 26: ...lon Cable available by the foot 55 0124 000 Junction Box 63 0169 000 RS 232 to RS 485 Converter Assembly Includes RS 232 to RS 485 converter with DB 9 RJ 11 Connectors and Standard Modular Cable length 7 feet 25 0134 001 40 Pocket Badge Rack Plastic 81 0117 000 8 wide x 225 8 high 2 12 Pocket Badge Racks Plastic 81 0116 003 37 8 wide x 14 high 40 Pocket Badge Rack Metal 81 0113 000 41 2 wide x 32 ...

Page 27: ...ing procedure for selecting PORTS Swipe the Configuration Badge 000000000 This badge is provided with each terminal Select option 2 for Ports press ENTER Select option 0 for RS232 press ENTER Select the baud rate 0 for 1200 1 for 2400 2 for 4800 3 for 9600 and 4 for 19 200 baud press ENTER For modem terminal only Select option 1 for Modem press ENTER Select the Modem baud press ENTER Select the An...

Page 28: ...ask TCPIP number contains four groups of numbers separated by To determine the NETMASK VALUE obtain your default Subnet IP number from the Network administrator XXX 125 125 125 for your server Default Subnet convert each 125 your numbers will be different to binary and count the number of zero s in the binary number and enter this number 125 01111101 in binary Each 125 has two zeros therefore the ...

Page 29: ...the IN then the OUT and then the ENTER key within 1 second The terminal will go into a testing mode Press the Clear key followed by Press the IN then the OUT and then the ENTER key within 1 second or before the time is displayed Fingerprint Reader for units equipped with Fingerprint Reader Enabling Fingerprint Reader 1 Swipe the configuration badge 2 Select option 2 for CONFIG press ENTER 3 Press ...

Page 30: ...l IO 10 4 Printer Data 2 5 Digital IO 11 5 Printer Data 3 6 Digital IO 12 6 Printer Data 4 7 Digital IO 13 7 Printer Data 5 8 Digital IO 14 8 Printer Data 6 9 Digital IO 15 9 Printer Data 7 10 N A 10 ACK 11 Digital IO 2 11 Busy 12 Digital IO 3 12 PE 13 Digital IO 4 13 Slct 14 N A 14 Auto Feed 15 Digital IO 5 15 Error 16 Digital IO 6 16 Init 17 25 Ground 17 Slct 18 25 Ground 14 25 1 13 ...

Page 31: ...O 0 Output Only 3 Barcode Wand Receive Date 4 Ground 5 Access Logic Line Digital IO 1 Output Only 6 12 Volts Unregulated Max Current Draw 220mA with 3A Transformer Only DC7000 RS232 Connector 1 Not Used 2 CTS 3 Transmit Data from DC7000 4 Receive Data to DC7000 5 Ground 6 Not Used ...

Page 32: ... Connector Modem RS485 1 Not Used 1 GND 2 N A 2 N A 3 TIP 3 Data 4 RING 4 Data 5 N A 5 N A 6 Not Used 6 GND DC7000 Ethernet Connector 1 Data TX 2 Data TX 3 Data RX 4 Ground 5 Ground 6 Data RX 7 Power 8 Power 1 2 3 4 5 6 7 8 ...

Page 33: ...oints 2 15 Output High 1 6 milliamps out of MAX V out 2 4 Volts MIN Low 2 0 milliamps in MAX V out 0 4 Volts MAX Input Input Voltage Range 0 5 Volts High 2 2 Volts MIN Low 0 8 volts MAX NOTE If a barcode wand is used the wand s electric current must be included in your total current calculation IBM is a registered trademark of International Business Machines ...

Page 34: ...34 This page intentionally left blank ...

Page 35: ...35 This page intentionally left blank ...

Page 36: ...36 5640 Departure Drive Raleigh NC 27616 919 872 5800 www acroprint com P N 06 0333 000 Rev B ...