![Acromag PMC341 Series User Manual Download Page 21](http://html1.mh-extra.com/html/acromag/pmc341-series/pmc341-series_user-manual_2841184021.webp)
SERIES PMC341 PCI MEZZANINE CARD SIMULTANEOUS ANALOG INPUT MODULE
___________________________________________________________________________________________
- 20 -
APPENDIX
CABLE: MODEL 5028-187 (SCSI-2 to Flat Ribbon, Shielded)
Type: Round shielded cable, 50-wires (SCSI-2 male connector at
one end and a flat female ribbon connector at the other end).
The cable length is 2 meters (6.56 feet). This shielded cable
is recommended for all I/O applications (both digital I/O and
precision analog I/O).
Application: Used to connect Model 5025-552 termination panel
to the PMC330 Module.
Length: Standard lenght is 2 meters (6.56 feet). Consult factory
for other lenghts. It is recommended that this length be kept
to a minimum to reduce noise and power loss.
Cable: 50 conductors, 28 AWG on 0.050 inch centers (permits
mass termination for IDC connectors), foil/braided shield
inside a PVC jacket.
Connectors: (One End): SCSI-2, 50-pin male connector with
backshell and spring latch hardware.
(Other End): IDC, 50-pin female connector with
strain relief.
Keying: The SCSI-
2 connector has a “D Shell” and the IDC
connector has a polarizing key to prevent improper
installation.
Schematic and Physical Attributes: See Drawing 4501-758.
Electrical Specifications: 30 VAC per UL and CSA (SCSI-2
connector spec.’s). 1 Amp maximum at 50% energized
(SCSI-
2 connector spec.’s).
Operating Temperature: -20
C to +80
C.
Storage Temperature: -40
C to +85
C.
Shipping Weight: 1.0 pound (0.5Kg), packed.
TERMINATION PANEL: MODEL 5025-552
Type: Termination Panel For PMC Module Boards
Application: To connect field I/O signals to the PMC Module.
Termination Panel:
Acromag Part 4001-040 (Phoenix
Contact Type FLKM 50). The 5025-552 termination panel
facilitates the connection of up to 50 field I/O signals and
connects to the PMC Module (connectors only) via a flat
ribbon cable (Model 5025-551-x). Field signals are accessed
via screw terminal strips. The terminal strip markings on the
termination panel (1-50) correspond to field I/O (pins 1-50) on
the PMC module. Each PMC module has its own unique pin
assignments. Refer to the PMC module manual for correct
wiring connections to the termination panel.
Schematic and Physical Attributes: See Drawing 4501-464.
Field Wiring: 50-position terminal blocks with screw clamps.
Wire range 12 to 26 AWG.
Mounting: Termination panel is snapped on the DIN mounting
rail.
Printed Circuit Board: Military grade FR-4 epoxy glass circuit
board, 0.063 inches thick.
Operating Temperature: -40
C to +100
C.
Storage Temperature: -40
C to +100
C.
Shipping Weight
: 1.25 pounds (0.6kg) packaged.