Quick Overview
–
Android Reconfiguration...continued
Performing Diagnostics (Polling & Trending the Inputs)
The Diagnostic Center screen tab is shown at left and used to verify input
(ADC) operation of your transmitter. This page can be used to poll the
input data and display its value or graph the input data and trend its value.
The input type currently set is shown at the top of the screen (the input
value, not the scaled input value is polled).
Select the Indicator pointer to set your desired indication to
“Digital”
(value)
or “Graph”
(trend).
You can specify a polling period to set the interval between polled
readings by over-typing the value in the Polling Period field.
Start polling the input by tapping the
[START POLLING]
button.
Clear the polling data by tapping
[CLEAR DATA].
Check the “Save Data” box if you wish to log the polled values to a CSV
(Comma Separated Value) data file for reference.
Note the Communication Status of the device is indicated at the bottom of
the screen.