background image

INDUSTRIAL I/O PACK SERIES AVME9630/9660                                        VMEbus 3U/6U CARRIER BOARDS 
___________________________________________________________________________________________

 

- 15 - 

Interrupts....................................Supports two interrupt requests 
                                                   per IP and interrupt acknowledge 
                                                   cycles, D16/D08(O). 
 
 

APPENDIX 

 

CABLE:  MODEL 5025-550-x (Non-Shielded) 
                MODEL 5025-551-x (Shielded) 

 
Type:  Flat Ribbon Cable, 50-wires (female connectors at both 

ends).  The ‘-x’ suffix designates the length in feet (12 feet 
maximum).  Choose shielded or unshielded cable according to 
model number.  The unshielded cable is recommended for 
digital I/O, while the shielded cable is recommended for 
optimum performance with precision analog I/O applications. 

Application:  Used to connect Model 5025-552 termination panel to 

the AVME9630/9660 non-intelligent carrier board A-D 
connectors (Both have 50-pin connectors). 

Length:  Last field of part number designates length in feet (user-

specified, 12 feet maximum).  It is recommended that this 
length be kept to a minimum to reduce noise and power loss. 

Cable:  50-wire flat ribbon cable, 28 gage.  Non-Shielded cable 

model uses Acromag Part 2002-211 (3M Type C3365/50 or 
equivalent).  Shielded cable model uses Acromag Part 2002-
261 (3M Type 3476/50 or equivalent). 

Headers (Both Ends):  50-pin female header with strain relief.  

Header - 

Acromag Part 1004-512 (3M Type 3425-6600 or 

equivalent).  

Strain Relief -

 Acromag Part 1004-534 (3M Type 

3448-3050 or equivalent).  

Keying:  Headers at both ends have polarizing key to prevent 

improper installation. 

Schematic and Physical Attributes:  For Non-Shielded cable model, 

see Drawing 4501-462.  For Shielded cable model, see 
Drawing 4501-463. 

Shipping Weight:  1.0 pound (0.5Kg), packed. 
 
 

TERMINATION PANEL:  MODEL 5025-552

 

 
Type:  Termination Panel For AVME9630/9660 Boards 
Application:  To connect field I/O signals to the Industrial I/O Pack 

(IP).  

Termination Panel:  

Acromag Part 4001-040  (Phoenix 

Contact Type FLKM 50).  The 5025-552 termination panel 
facilitates the connection of up to 50 field I/O signals and 
connects to the AVME9630/9660 3U/6U non-intelligent carrier 
boards (A-D connectors only) via a flat ribbon cable (Model 
5025-550-x or 5025-551-x).  The A-D connectors on the carrier 
board connect the field I/O signals to the P2 connector on each 
of the Industrial I/O Pack modules.  Field signals are accessed 
via screw terminal strips.  The terminal strip markings on the 
termination panel (1-50) correspond to P2 (pins 1-50) on the 
Industrial I/O Pack (IP).  Each Industrial I/O Pack (IP) has its 
own unique P2 pin assignments.  Refer to the IP module 
manual for correct wiring connections to the termination panel. 

Schematic and Physical Attributes:  See Drawing 4501-464. 
Field Wiring:  50-position terminal blocks with screw clamps.  Wire 

range 12 to 26 AWG. 

Connections to AVME9630/9660:  P1, 50-pin male header with 

strain relief ejectors.  Use Acromag 5025-550-x or 5025-551-x 
cable to connect panel to VME board.   Keep cable as short as 
possible to reduce noise and power loss. 

Mounting:  Termination panel is snapped on the DIN mounting rail. 

Printed Circuit Board:  Military grade FR-4 epoxy glass circuit 

board, 0.063 inches thick. 

Operating Temperature:  -40

°

C to +100

°

C. 

Storage Temperature:  -40

°

C to +100

°

C. 

Shipping Weight 

:  1.25 pounds (0.6kg) packed. 

 

TRANSITION MODULE: MODEL TRANS-GP 

 
Type:  Transition module for AVME9630/9660 boards. 
Application:  To repeat field I/O signals of IP modules A through D 

for rear exit from VME card cages.  This module is available for 
use in card cages which provide rear exit for I/O connections 
via transition modules (transition modules can only be used in 
card cages specifically designed for them).  It is a double-
height (6U), single-slot module with front panel hardware 
adhering to the VMEbus mechanical dimensions, except for 
shorter printed circuit board depth.  Connects to Acromag 
termination panel 5025-552 from the rear of the card cage, and 
to AVME9630/9660 boards within card cage, via flat 50-pin 
ribbon cable (cable Model 5025-550-X or 5025-551-X). 

Schematic and Physical Attributes:  See Drawing 4501-465. 
Field Wiring:  100-pin header (male) connectors (3M 3433-D303 or 

equivalent) employing long ejector latches and 30 micron gold 
in the mating area (per MIL-G-45204, Type II, Grade C).  
Connects to Acromag termination panel 5025-552 from the 
rear of the card cage via flat 50-pin ribbon cable (cable Model 
5025-550-X or 5025-551-X). 

Connections to AVME9630/9660: 50-pin header (male) connectors 

(3M 3433-1302 or equivalent) employing long ejector latches 
and 30 micron gold in the mating area (per MIL-G-45204, Type 
II, Grade C).  Connects to AVME9630/9660 boards within the 
card cage via flat 50-pin ribbon cable (cable Model 5025-550-X 
or 5025-551-X). 

Mounting:  Transition module is inserted into a 6U-size, single-

width slot at the rear of the VMEbus card cage. 

Printed Circuit Board:  Six-layer, military-grade FR-4 epoxy glass 

circuit board, 0.063 inches thick. 

Operating Temperature:  -40 to +85

°

C. 

Storage Temperature:  -55

°

C to +105

°

C. 

Shipping Weight:  1.25 pounds (0.6Kg) packed. 

Summary of Contents for AVME9630 Series

Page 1: ...rutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In sto...

Page 2: ...Carrier Boards USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 1994 Acromag Inc Printed in the USA Data and...

Page 3: ...Circuitry 12 IP Read and Write Cycle Timing 12 VME Interrupter 12 Power Failure Monitor 13 Assess LEDs and Pulse Stretcher Circuitry 13 Power Supply Filters 13 5 0 SERVICE AND REPAIR 13 SERVICE AND RE...

Page 4: ...pace is used for all carrier registers and IP module I O and ID spaces The carrier board base address is set by hardware jumpers and decoded on 1K byte boundaries Supports Standard I O Address Modifie...

Page 5: ...Drawing 4501 450 Power should be removed from the board when installing IP modules cables termination panels and field wiring Refer to Mechanical Assembly Drawing 4501 434 and your IP module document...

Page 6: ...rity and utilizes gold plating in the mating area Threaded metric M2 screws and spacers supplied with Acromag IP modules provide additional stability for harsh environments see Drawing 4501 434 for as...

Page 7: ...of wait states multiplied by 125nS the period of the 8 MHz clock FIELD GROUNDING CONSIDERATIONS Carrier boards are designed with passive filters on each supply line to each IP module This provides max...

Page 8: ...standard A24 address space if needed for IP modules containing Memory space IP memory will only be mapped into the standard memory space if it is enabled for a particular IP per the user programmable...

Page 9: ...ere Bits 7 Writing a 1 to this bit will enable automatic clear of pending interrupts on the carrier When this bit is set pending interrupts will not be latched or registered on the carrier An interrup...

Page 10: ...6 5 4 Not used equal 0 if read Bit 3 IP D Memory Enable Read Write Writing a 1 to this bit enables the memory space for IP D A zero disables memory space accesses Reset Condition Set to 0 memory space...

Page 11: ...ules pending interrupt status even if the IP interrupt enable bit is set to 0 Reset Condition Set to 0 IP Interrupt Clear Register Write Base E5H The IP Interrupt Clear Register is used to individuall...

Page 12: ...nterrupting IP by writing a 0 to the appropriate bit in the IP Interrupt Enable Register B Take any IP specific action required to remove the interrupt request at its source C Clear the interrupting I...

Page 13: ...spond to two IP module interrupt requests per IP with software programmable VMEbus interrupt levels Carrier Board Clock Circuitry The VMEbus 16MHz system clock is divided down by the FPGA to obtain th...

Page 14: ...duration of 0 1 seconds typical Power Supply Filters Power line filters are dedicated to each IP module for filtering of the 5 12 and 12 volt supplies The power line filters are a T type filter circu...

Page 15: ...cation This device meets or exceeds all written VME specifications per revision C 1 dated October 1985 IEC 821 1987 and IEEE 1014 1987 Data Transfer Bus A24 A16 D16 D08 EO DTB slave supports Read Modi...

Page 16: ...rrespond to P2 pins 1 50 on the Industrial I O Pack IP Each Industrial I O Pack IP has its own unique P2 pin assignments Refer to the IP module manual for correct wiring connections to the termination...

Page 17: ...INDUSTRIAL I O PACK SERIES AVME9630 9660 VMEbus 3U 6U CARRIER BOARDS ___________________________________________________________________________________________ 16...

Page 18: ...RIBBON CABLE NON SHIELDED 1004 512 1004 534 4501 462 AVME9630 9660 CARRIER BOARD MODEL 5025 552 I O TERMINATION TOP VIEW CONNECTOR 1004 512 IS DESIGNATED WITH RED INK STRAIN RELIEF SEVEN DIGIT PART N...

Page 19: ...23 29 22 25 28 38 32 35 37 31 34 44 43 40 50 49 3 67 93 1 TERMINATION PANEL 2 72 15 48 14 13 47 46 SIDE VIEW TOLERANCE 0 020 0 5 2 44 62 0 ENGINDOC DRIVE FRONT VIEW CABLE 5025 551 x SHIELDED NUMBER 40...

Page 20: ...INDUSTRIAL I O PACK SERIES AVME9630 9660 VMEbus 3U 6U CARRIER BOARDS ___________________________________________________________________________________________ 19...

Page 21: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: