![Acromag AcroPack AP471 Series User Manual Download Page 34](http://html1.mh-extra.com/html/acromag/acropack-ap471-series/acropack-ap471-series_user-manual_2841147034.webp)
SERIES AP471 ACROPACK
USER
’S MANUAL
Acromag, Inc. Tel: 248-295-0310
- 32 -
http://www.acromag.com
- 32 -
www.acromag.com
AP-CC-01 AcroPack Conduction Cool Kit (See Appendix B for
installation instructions)
6.3.2 Relative Humidity
The range of acceptable relative humidity is 5% to 95%, non-condensing.
6.3.3 Isolation
The PCIe bus and field commons are non-isolated and have a direct electrical
connection.
6.3.4 Vibration and Shock Standards
The AcroPack is designed to meet the following Vibration and Shock
standards.
Vibration, Sinusoidal Operating: Designed to comply with IEC 60068-2-6:
10-500Hz, 5G, 2 Hours/axis
Vibration, Random Operating: Designed to comply with IEC 60068-2-64: 10-
500Hz, 5G-rms, 2 Hours/axis
Shock, Operating: Designed to comply with IEC 60068-2-27: 30G, 11ms half
sine, 50G, 3mS half sine, 18 shocks at 6 orientations for both test levels
6.3.5 EMC Directives
The AcroPack complies with EMC Directive 2014/30/EU.
Immunity per EN 61000-6-2:
Electrostatic Discharge Immunity (ESD), per IEC 61000-4-2.
Radiated Field Immunity (RFI), per IEC 61000-4-3.
Electrical Fast Transient Immunity (EFT), per IEC 61000-4-4.
Surge Immunity, per IEC 61000-4-5.
Conducted RF Immunity (CRFI), per IEC 61000-4-6.
Emissions per EN 61000-6-4:
Enclosure Port, per CISPR 16.
Low Voltage AC Mains Port, per CISPR 16.
Note: This is a Class A product