![Acrel DDSY1352 Operation Manual Download Page 20](http://html1.mh-extra.com/html/acrel/ddsy1352/ddsy1352_operation-manual_2841079020.webp)
16
0360H
Main
communication
:
Communication
address and baud
rate
UINT8
×
2
R/W
Communication parameters
with ddsy1352
0361H
The main
communication
:
Check bit stop bit
UINT8
×
2
R/W
0362H-0364H
Reserved
0365H
Deputy
communication:Com
munication address
and baud rate
UINT8
×
2
R/W
Communication parameters
with DDSY1352
0366H
Deputy
communication:Chec
k bit stop bit
UINT8
×
2
R/W
0367H-0369H
036AH-1FFFH
Reserved
2000H
Schedule 1:
Session 1 tariff
number
Starting Time of
session 1: Minutes
Starting Time of
session 1: hours
……
Section 14 tariff
number
Starting Time of
session 14: minutes
Session 14 starting
time: Hours
INT8
×
42
R/W
Rate Number:
01 for Pointy
02 for peaks
03 for Ping
04 for Valley
2015H
Schedule 2:
Session 1 tariff
number
Starting Time of
session 1: Minutes
Starting Time of
session 1: hours
……
Section 14 tariff
number
Starting Time of
session 14: minutes
INT8
×
42
R/W
Rate Number:
01 for Pointy
02 for peaks
03 for Ping
04 for Valley