primary air slider to the right hand side of
the door by fully pushing the levers
inwards.

• Lay firelighters or rolled up newspapers

on the grate and add a small amount of
kindling wood to the top. Place a small
quantity of smokeless fuel on top.

• Light the newspaper or firelighters using

a long taper and push the door closed
but do not engage the locking handle
fully.

• When the fire is burning fiercely, after a

couple of minutes add more  smokeless
fuel and close the door.

• When the fire has become established,

close the secondary air by 50%, to the
left hand side of the door, by pulling  the
lever outwards.

• The burning rate can be altered by

moving the primary air slide, to the right
hand side of the door - pull the lever
outwards to close down and push the
lever inwards to increase the burn rate.

• Care should be taken to ensure that the

firebox is not overfilled with smokeless
fuel - it should be no higher than the log
guard. 

Re-fueling 

When refueling the stove 

always refuel

onto a bed of hot embers

, fully open the

secondary and primary air controls until
the new fuel is well alight, before adjusting
the air controls for the desired setting.

If there is insufficient burning material in
the firebed to light a new fuel charge,
excessive smoke emission can occur.
Refueling must be carried out onto a
sufficient quantity of glowing embers and
ash that the new fuel charge will ignite in a
reasonable period. If there are too few
embers in the fire bed, add suitable
kindling to prevent excessive smoke.

Fuel overloading 

Never overload the stove - it will work very
well with two medium sized logs. The
amount of fuel specified in this manual

should not be exceeded, overloading can
cause excess smoke.

Glass 

Never operate the appliance if the glass
panel is broken or cracked. This can cause
the appliance to overfire, which may
damage the appliance and flue system
and may cause a danger to persons and
property. Only use once the glass is
replaced and the sealing gaskets checked
for integrity, only replace with a
manufactures approved glass.

Operation with door left open 

Operation with the door open can cause
excess smoke and overfiring of the
appliance. The appliance must not be
operated with the appliance door left open
except as directed in the instructions.

Dampers left open  

Operation with the air controls or
appliance dampers open can cause
excess heat within the appliance. The
appliance must not be operated with air
controls, appliance dampers or door left
open except as directed in the
instructions.

Never leave the stove unattended
until the new fuel is well alight.

Persistent fume emission is
dangerous and must be
investigated

.  

If fume emission persists, open doors and
windows to ventilate the room and let the
fire die out. Have the chimney inspected
for blockages and clean if required. Do not
relight the fire until the cause has been
found. We recommend that you seek
professional advice.

This appliance has been designed to be
burned with the door closed at all times
other than when refueling.

It should not be operated as an open fire.

Typical refueling intervals for wood is 1
hour and smokeless fuel is 2 hours.

11

Tenbury T400 install manual NEW 2020-0320-7  16/03/2020  14:05  Page 11

Summary of Contents for Tenbury T400ECO

Page 1: ...rence Thank you for purchasing an ACR Heat Products stove T E C H N I C A L M A N U A L Document T400ECO 0101 Version 1 Date 02 03 20 Serial Number MULTI FUEL DEFRA EXEMPT AIRWASH SYSTEM 10 YEAR 10 YE...

Page 2: ...contact with the appliance This appliance has been designed for intermittent operation This appliance must not be used as an incinerator Each installation is unique to the property the information co...

Page 3: ...initial 3 minutes Height 550 mm Internal Box 588 mm External Trim Width 396 mm Internal Box 470 mm External Trim Depth 337 mm Recessed 347 mm External Trim Weight 60 kg Air Requirement N A Flue Mass G...

Page 4: ...Technical Data Declaration of Performance 4 Tenbury T400 install manual NEW 2020 0320 7 16 03 2020 14 05 Page 4...

Page 5: ...16 of the Environmental Better regulation Act Northern Ireland 2016 In Wales appliances are exempted by regulations made by Welsh Ministers The Tenbury T400Eco has been recommended as suitable for us...

Page 6: ...od This appliance must be installed by a registered engineer or approved by building control failure to do so may endanger life and property All the below instructions should work in conjunction with...

Page 7: ...onstructed of a non combustible material i e metal studwork Do not use combustible materials within the chequered area 200mm to the sides of the appliance and 300mm to the rear of the appliance Do not...

Page 8: ...ce Flue Requirements The flue must comply with current Building Regulations Document J The construction of masonry flue block insulated flue systems and flexible flue liners must comply with the manuf...

Page 9: ...place and replace the 6 x 10mm screws replace the baffle and install the trim if not already in place 3 4 5 6 7 8 Operating your stove Using your appliance for the first time To allow the appliance t...

Page 10: ...combustion of the wood logs Open the secondary air slider to the left hand side of the door and open the primary air slider to the right hand side of the door by fully pushing the levers inwards Lay f...

Page 11: ...Fuel overloading Never overload the stove it will work very well with two medium sized logs The amount of fuel specified in this manual should not be exceeded overloading can cause excess smoke Glass...

Page 12: ...ite panels of the appliance should be checked regularly for soundness If any wear and tear is found we recommend these parts are replaced immediately Check the rope door seals are intact and are not w...

Page 13: ...l starts to crumble and fall apart in chunks To prevent the issue from happening and prolong the life of your internal panels the homeowner should burn in the refractory panels in the new appliance by...

Page 14: ...ke test Record flue draught reading Spillage test preformed in accordance with available guidance Check socket joints and seals on the flue and appliance Instruct user on correct fuels and fuel storag...

Page 15: ...top removing tool 11 TB 02 11 05A Primary air slider 12 TB 02 11 04A Secondary Tertiary air slider 13 TB 02 30 01A Left hand vermiculite panel 14 TB 02 30 03A Right hand vermiculite panel 15 TB 02 30...

Page 16: ...easoned wood 20 moisture content Low flue draught Consult your installer for advice on suitable flue system Incorrect use of air control See user instructions for correct use of air control Appliance...

Page 17: ...t your installer for advice on suitable flue system Incorrect additional ventilation air into building Consult your installer Continuous smoke spillage into room when appliance in use Blocked flue Ope...

Page 18: ...Address Postcode Daytime Tel Mobile Tel Model Name Model Number Serial Number Date of purchase Date of installation Installer s Name and address Installer s Registration Number Building Control Certif...

Page 19: ...ordance with our instruction manual All Stoves are covered by a 10 year warranty which covers all stove body castings stove body steel panels It does not include consumable items such as glass door se...

Page 20: ...ted Unit 1 Weston Works Weston Lane Tyseley Birmingham B11 3RP England Tel 0121 706 8266 E mail enquiries acrheatproducts co uk www acrheatproducts co uk Tenbury T400 install manual NEW 2020 0320 7 16...

Reviews: