background image

IMPORTANT INFORMATION

• Before installation and/or use of this

appliance please read these instructions
carefully to ensure that all requirements are
fully understood. 

• This appliance must be installed by a

registered engineer, or approved by building
control, failure to do so may endanger life and
property.

• All the instructions in this manual should work

in conjuction with building regulations
document J, if there is a variation the most
stringent requirement should be adhered to.

• The installation of this appliance must comply

with current Building Regulations and local
regulations, including those referring to
national and European standards need to be
complied with when installing the appliance. 

• Do not operate this appliance if it becomes

damaged.

• Improper use, maintenance or fitting parts

other than those approved by the
manufacturer could lead to the appliance
becoming damaged or unsafe which in turn
could lead to personal injury or damage to
the property and will void the warranty.

• The appliance must not be modified in

anyway unless authorised by ACR Heat
Products Ltd.

• The appliance should be inspected regularly

to ensure the airways are clean and free from
obstruction and the chimney swept at least
once a year.

• The external surfaces of this appliance will be

very hot to the touch when in operation and
due care will need to be taken when
operating the appliance to ensure safety. A
fire guard should be fitted if it is likely that the
elderly, infirm or children may come into
contact with the appliance. 

• This appliance has been designed for

intermittent operation.

• This appliance must not be used as an

incinerator.

• Each installation is unique to the property, the

information contained in this manual may not
give exact installation requirements for your
installation.

• The installation must comply with Building

Regulations, European Standards and Local
authority bylaws.

Asbestos

This appliance contains no asbestos, if there is
the possibility of disturbing any asbestos in the
installation of this appliance then specialist
advise must be sought and appropriate
precautions taken.

Metal Parts

This appliance may contain sharp metal edges,
take care when installing or servicing this
appliance to avoid personal injury. Please use
appropriate personal protective equipment at
all times.

To ensure that you gain the most from your purchase, please take a few minutes

to read through this manual before lighting the appliance for the first time.

Since April 2002 only registered competent installers can install solid fuel appliances. Installations

carried out by non-registered installers must be inspected by local authority building control. 

For more information please contact hetas at: www.hetas.co.uk or telephone: 0845 6345626

Before installation, please ensure that the correct model has been supplied. 

Please make a note of the serial number of your appliance in the space provided on the front cover

of this manual as this will be requested if you require technical assistance in the future.

Please also ensure that the commissioning checklist at the rear of the manual is completed in full.

Summary of Contents for Earlswood III

Page 1: ...To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove T E C H N I C A L M A N U A L EW3MF 0101 Version 1 Date 18 07 16 Serial Number MULTI FUEL SMOKE EXEM...

Page 2: ...elderly infirm or children may come into contact with the appliance This appliance has been designed for intermittent operation This appliance must not be used as an incinerator Each installation is u...

Page 3: ...ered installer for advice If installing into a room containing an extractor fan please ensure that the relevant tests are carried out according to Document J of the building regulations Nominal heat o...

Page 4: ...es used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations Earlswood EW3...

Page 5: ...t and if installed into a recess enough space should be left around the appliance to enable the heat produced to rise and escape from the recess back into the room Hearth Requirements The appliance mu...

Page 6: ...appliance is equipped with a pre fitted manufacturers smoke exempt stop Under no circumstances should it be tampered with or removed unless expressly authorised by a competent person and the applianc...

Page 7: ...wood such as ash oak and beech which have been cut for at least 2 years and stored under shelter The logs should have a maximum moisture content of 20 Maximum log length 350mm maximum width 150mm Smok...

Page 8: ...taken to ensure that the logs are not placed higher than the log guard allows Instructions for use with smokeless fuel Pull the secondary air slider under the ashlip and open the primary air slider f...

Page 9: ...d between the ash below it and above it This will overheat the grate and cause distortion and premature wear Operating your stove Operation with door left open Operation with the door open can cause e...

Page 10: ...d be replaced on an annual basis to ensure the correct operation of this appliance The glass can be cleaned using a soft damp cloth or a ceramic glass cleaner available from your local stockist Use on...

Page 11: ...f the appliance Leave the instruction manuals operating tool and glove for the customer s use Record the flue draught reading of the appliance Please tick boxes when each procedure is completed To rem...

Page 12: ...1 3 2 4 5 8 9 34 34 34 29 30 28 27 32 40 10 39 35 38 20 21 22 26 25 14 15 17 19 18 16 13 23 24 37 11 12 36 33 31 7 6 Parts Information...

Page 13: ...047 1 20 Rear Vermiculite Brick 6081 1005 1 21 Rear Tertiary Air Chamber 3811 864 1 22 Steel Body Complete 3311 1016 1 23 Rear Air Separation Chamber 3811 844A 1 24 Blanking Plate Gasket 8400 276B 1 2...

Page 14: ...den defects subject to the following conditions The appliance must have been installed by a registered competent installer e g HETAS or inspected by local authority Building Control The appliance must...

Page 15: ...06 8266 Fax 0121 706 9182 E mail enquiries acrheatproducts co uk www acrheatproducts co uk Customer Name Customer Address Postcode Daytime Tel Mobile Tel Model Name Model Number Serial Number Date of...

Page 16: ...ACR Heat Products Limited Unit 1 Weston Works Weston Lane Tyseley Birmingham B11 3RP England Tel 0121 706 8266 Fax 0121 706 9182 E mail enquiries acrheatproducts co uk www acrheatproducts co uk...

Reviews: