Assembly of the unit

• Remove the internal vermiculite baffle

(for further instruction please see
under maintenance heading).

• Remove the rear metal cut out plate

from the back of the stove

• Remove the rear blanking plate

• Remove the flue spigot from the top

exit by removing the securing bolts
and rope seal 

• Refit the rope seal and flue spigot to

the rear exit and secure with the bolts 

• Refit the blanking plate to the top exit

using the rope seal and retaining bolts

This appliance is equipped with a pre-fitted manufacturers smoke exempt stop. Under

no circumstances should it be tampered with or removed unless expressly authorised

by a competent person and the appliance is not installed in a smoke exempt area.

If the appliance is to be installed in a non smoke exempt area you can remove the
restricting screw on the secondary air control (on right hand side under the ash lip) 
to allow full movement of the secondary air slider.

The appliance is supplied pre-assembled with the flue spigot in the top exit position. 

If you intend to install the appliance using a rear flue connection, the blanking plate should be
swapped over as follows: 

Summary of Contents for Earlswood III

Page 1: ...To be retained by the user for future reference Thank you for purchasing an ACR Heat Products stove T E C H N I C A L M A N U A L EW3MF 0101 Version 1 Date 18 07 16 Serial Number MULTI FUEL SMOKE EXEM...

Page 2: ...elderly infirm or children may come into contact with the appliance This appliance has been designed for intermittent operation This appliance must not be used as an incinerator Each installation is u...

Page 3: ...ered installer for advice If installing into a room containing an extractor fan please ensure that the relevant tests are carried out according to Document J of the building regulations Nominal heat o...

Page 4: ...es used to burn solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations Earlswood EW3...

Page 5: ...t and if installed into a recess enough space should be left around the appliance to enable the heat produced to rise and escape from the recess back into the room Hearth Requirements The appliance mu...

Page 6: ...appliance is equipped with a pre fitted manufacturers smoke exempt stop Under no circumstances should it be tampered with or removed unless expressly authorised by a competent person and the applianc...

Page 7: ...wood such as ash oak and beech which have been cut for at least 2 years and stored under shelter The logs should have a maximum moisture content of 20 Maximum log length 350mm maximum width 150mm Smok...

Page 8: ...taken to ensure that the logs are not placed higher than the log guard allows Instructions for use with smokeless fuel Pull the secondary air slider under the ashlip and open the primary air slider f...

Page 9: ...d between the ash below it and above it This will overheat the grate and cause distortion and premature wear Operating your stove Operation with door left open Operation with the door open can cause e...

Page 10: ...d be replaced on an annual basis to ensure the correct operation of this appliance The glass can be cleaned using a soft damp cloth or a ceramic glass cleaner available from your local stockist Use on...

Page 11: ...f the appliance Leave the instruction manuals operating tool and glove for the customer s use Record the flue draught reading of the appliance Please tick boxes when each procedure is completed To rem...

Page 12: ...1 3 2 4 5 8 9 34 34 34 29 30 28 27 32 40 10 39 35 38 20 21 22 26 25 14 15 17 19 18 16 13 23 24 37 11 12 36 33 31 7 6 Parts Information...

Page 13: ...047 1 20 Rear Vermiculite Brick 6081 1005 1 21 Rear Tertiary Air Chamber 3811 864 1 22 Steel Body Complete 3311 1016 1 23 Rear Air Separation Chamber 3811 844A 1 24 Blanking Plate Gasket 8400 276B 1 2...

Page 14: ...den defects subject to the following conditions The appliance must have been installed by a registered competent installer e g HETAS or inspected by local authority Building Control The appliance must...

Page 15: ...06 8266 Fax 0121 706 9182 E mail enquiries acrheatproducts co uk www acrheatproducts co uk Customer Name Customer Address Postcode Daytime Tel Mobile Tel Model Name Model Number Serial Number Date of...

Page 16: ...ACR Heat Products Limited Unit 1 Weston Works Weston Lane Tyseley Birmingham B11 3RP England Tel 0121 706 8266 Fax 0121 706 9182 E mail enquiries acrheatproducts co uk www acrheatproducts co uk...

Reviews: