OWL Data Logger
4
Copyright © 2010 ACR Systems Inc. All Rights Reserved.
Do not rely on the logger's magnetic strip for adhesion if the mounting surface is uneven,
unstable or above 65° C (150°F).
Keep Track
Make sure to keep a record of where you have placed each logger in a building or system
plan. You will save time looking for them when your data gathering session is over. Also,
keep track of when you placed the loggers in the area you are monitoring. This will help when
producing graphs on your computer. It may be helpful to label (shipping tag) each logger so
you can properly identify and differentiate it from other loggers.
Analysis
After sufficient time has passed for the logger to obtain a representative profile of data, it is
time to analyze the information. If you are retrieving the logger from the field, bring it back
immediately to your computer for analysis.
In order to analyze your OWL logger's data, you must first transfer a backup copy of its data to
your computer. To do this, see Backup in the TrendReader guide. After transferring your
information to the computer, the data is automatically copied to disk and time and date
stamped.
You can find a detailed description of all software functions in the TrendReader guide.
1.1.6
General Specifications
General
Size:
60 x 48 x 19mm (2.4" x 1.9" x 0.75")
Case Material:
Polyurethane
Case Weight:
80g (2.8 oz.)
Snapcase Material:
Noryl® Plastic
Snapcase Weight:
54g (1.9 oz.)
Operating Limits:
-40 to 70°C. (-40 to 158°F.) and 0 to 95% RH
(non-condensing)
Clock Accuracy:
+/-2 seconds/day
Battery:
3.6 Volt Lithium, 1 Amp-hour
Power Draw:
5 to 10 microamps (continuous)
Battery Life:
Ten years projected
Alarm Type:
Optical red LED
Memory and Data Inputs
Memory Size:
32,767 readings
Summary of Contents for OWL 100
Page 3: ...TrendReader is a Registered Trademark of ACR Systems Inc TRADEMARK NOTICES ...
Page 4: ......
Page 44: ...OWL Data Loggers 37 Copyright 2010 ACR Systems Inc All Rights Reserved ...
Page 45: ...OWL Data Logger 38 Copyright 2010 ACR Systems Inc All Rights Reserved ...
Page 46: ...OWL Data Loggers 39 Copyright 2010 ACR Systems Inc All Rights Reserved ...
Page 48: ...OWL Data Loggers 41 Copyright 2010 ACR Systems Inc All Rights Reserved ...
Page 49: ...OWL Data Logger 42 Copyright 2010 ACR Systems Inc All Rights Reserved ...
Page 50: ...OWL Data Loggers 43 Copyright 2010 ACR Systems Inc All Rights Reserved ...
Page 54: ......
Page 55: ......