Page 27
AB-G200L-REM-I01-150914
CLEANING
Ensure that the stove is turned off before cleaning and is cold.
DO NOT use abrasive cleaning agents.
The stove is supplied with ceramic logs that should only be cleaned and arranged by a
qualified person in accordance with the Installation Instructions.
SERVICING
It is essential that the stove is regularly serviced, and the flue system checked by a
qualified person.
Servicing Instructions
The stove is fitted with a spillage monitoring system consisting of a thermal switch
connected to a thermocouple interrupter. This system is not adjustable and must not be
put out of action. If any parts of the spillage monitoring system require replacement
only original manufacturers’ parts must be used.
The thermal switch rating is 120°C. Quote this rating if ordering a new switch.
1.
The following servicing procedure should be carried out regularly and only by a
qualified person.
Ensure that the fire is turned off and is cold.
2.
If fitted, remove the screw securing the door handle and open the stove door.
3.
Remove the ceramics in the reverse order to that described in POSITIONING THE
LOGS section (p.7 or 11).
4.
Remove and deposition of dirt, lint etc. carefully from the burner flame strip, tray
and pilot assembly with a soft brush.
5.
Due to the intense temperatures reached in the fire, some surface cracks may
appear on the ceramic components. This is quite normal and will not affect the safe
operation of the fire.
Replace the ceramics as described in the POSITIONING THE LOGS section (p.7 or
11).
6.
Close the stove door; replace the screw securing the door handle or door.
7.
Check the supply pressure as described in the TECHNICAL INFORMATION section
(p.3).
8.
Ensure correct operation of the flue as described in CHECK FOR SPILLAGE section
(p.8).