Page 13
AB-G200L-REM-I01-150914
1
Red indicator LED:
OFF
: Burner is in standby and ready for start, or already in continuous operation
Fast flashing
: Control unit is busy and will not accept commands.
Medium fast flashing
: Control unit is preparing a (re)start of the burner.
Slow flashing
: Control unit is detecting an error.
One short flash every 8 seconds
: Low battery warning.
Always ON
: Burner is locked.
2
Master switch
:
Left position
: Control unit is disconnected from all power supplies and does not
consume power.
Right Position
: Control unit is powered and ready to operate.
3
(-) Button
:
Burner in operation
: Use this button to reduce the power level.
4
ON/OFF Button
:
Burner in operation
: Use this button to stop burner operation.
Standby
: Use this button to start burner operation.
Burner locked
: Use this button to unlock the burner and to reset from error state.
If control unit is preparing to restart
: Use this button to stop the restart and
disable further automatic starts.
5
(+) Button:
Burner in operation: Use this button to increase the power level.
6
Battery box:
Insert here 3x AA-type Alkaline batteries.
7
Thermocouple connector.
8
High voltage and flame sensing output.
9
Gas inlet.
10 Pilot burner outlet.
11 Main burner outlet.
12 TTB connection socket.
13 Control unit mounting points.