![Acqua Brevetti PuliMATIC FT360 Installation And Operating Instructions Manual Download Page 38](http://html1.mh-extra.com/html/acqua-brevetti/pulimatic-ft360/pulimatic-ft360_installation-and-operating-instructions-manual_2840784038.webp)
PuliMATIC - ENGLISH
MAN141 PAGE E-11
The control panel (code 23022030) allows directly controlling up to two 24 Vac powered devices
(EVC solenoid valves, relay for pumps, alarms, etc.).
The panel has a specific input for the voltage-free contact with which PuliMATIC is equipped. The
connected devices are controlled by the panel when the voltage-free contact signal of the
PuliMATIC filter is received (washing stage). At the end of the washing procedure, a signal is sent
to switch off/close the devices connected to the panel.
A1.15 Other connections (optional)
Remove the rear cover by using a screwdriver, inserting it in the 2 slots, and proceed as shown in
the following figure:
under such cover there are four electrical connections:
PuliMATIC has two outputs for managing auxiliary equipment (e.g. solenoid valves,
alarms ...) and an input for the pressure differential switch to be connected as follows: