Component Specifications 

 

!

WARNING

 

 

To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor  

 

before servicing, unless testing requires power. 

January 2013 

 

16500051 

©2013 ACP, Inc.

 

5

 

Power Test 

All Amana and Menumaster microwave oven power outputs are rated using the IEC705 standards. Using the IEC705 
test method requires precision measurements and equipment that is not practical to be performed in the field. Using 
the test shown below will indicate if the oven performance is satisfactory. 

 

Test equipment required: 

 

1000 ml test container and thermometer.  

 

Digital watch / watch with a second hand for use on ovens with electromechanical timers. 

Important Notes: 

 

Low line voltage will cause low temperature rise / power output. 

 

Ovens must be on a dedicated circuit, properly grounded, and polarized. Other equipment on the same 
circuit may cause a low temperature rise / power output. 

 

This test and results are not a true IEC705 test procedure and are only intended to provide servicers with an 
easy means of determining if the microwave oven cooking output is correct. 

Procedure 

1.  Fill the test container to the 1000 ml line with cool tap water. 

NOTE:

 

Water temperature should be approximately 60°

 

F / 16°

 

C. 

2.  Using the thermometer, stir water for five to ten seconds; measure, and record the temperature (T1). 
3.  Place test container of water in the center of oven cavity and close door. 
4.  Heat the water for a 33-second full power cycle. 

NOTE:

 

Use a digital watch or a watch with a second hand for ovens with electromechanical timers. 

1.  At end of the cycle, remove test container. Using the thermometer, stir water for five to ten seconds and record 

temperature (T2). 

2.  Subtract the starting water temperature (T1), from the ending water temperature (T2) to obtain the temperature 

rise (

T). 

3.  If the temperature rise (

T) meets or exceeds the minimum, the test is complete. If the temperature rise (

T) 

fails to meet the minimum temperature rise, test the line voltage to verify it is correct. Then repeat steps 1-6 
making sure to change the water. If the temperature rise (

T) fails to meet the minimum temperature rise again 

the oven will require service. 

Minimum Temperature Rise at Thirty-Three (33) Seconds Run Time 

Cooking 

Cooking 

Cooking 

Cooking 

(°F) 

Power Output 

(°F) 

Power Output  

(°C) 

Power Output 

(°C) 

Power Output 

10.................. 1000 

20 ................. 2000 

5  ............... 1000 

11 ............ 2000 

11.................. 1100 

21 ................. 2100 

5.5 ............. 1100 

11.5 ......... 2100 

12.................. 1200 

22 ................. 2200 

6.5 ............. 1200 

12 ............ 2200 

14.................. 1400 

24 ................. 2400 

7.5 ............. 1400 

13 ............ 2400 

17.................. 1700 

25 ................. 2500 

9.5 ............. 1700 

13.5 ......... 2500 

18.................. 1800 

27 ................. 2700 

10 .............. 1800 

15 ............ 2700 

19.................. 1900 

30 ................. 3000 

10.5 ........... 1900 

16.5 ......... 3000 

 

Summary of Contents for P2002228M

Page 1: ...risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power Models DEC14E2A DEC18E2A Power Source Voltage AC 230 VAC 230 VAC Amperage single unit 16 A 16 A Frequency 50 Hz 50 Hz Single phase 3 wire earthed X X Power Output Nominal microwave energy IEC705 1400 Watts 1800 Watts Minimum temperature rise T 14ºF 7 5ºC...

Page 2: ...ed Infinite Approximately 40 Ω or more Infinite Infinite Capacitor Discharge Capacitors Remove wires from capacitor terminals and connect ohmmeter set on highest resistance scale to terminals Also check between each terminal and capacitor case Between Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occurs replace ...

Page 3: ...tely 12 KΩ Primary Logic Secondary Monitor Interlock switch assembly Disconnect wires to switch With door open measure resistance from Terminal C to NO Primary Terminal C to NO Secondary Terminal C to NC Monitor With door closed measure resistance from Terminal C to NO Primary Terminal C to NO Secondary Terminal C to NC Monitor Door Closed Primary Logic C NC NO C C NO Secondary Monitor Infinite In...

Page 4: ...otor antenna motor s and oven light Control board Terminals J4 1 J2 2 Cook relay Control board Terminals E1 E4 Line voltage All Conditions 0 VAC Idle and Standby 0 9 VAC Cook Line voltage Idle 0 VAC Standby and Cook Line voltage Idle 0 volts Standby and Cook Error Code Table Error Code Corrective Action F1 Replace HV LV Board F2 Replace HV LV Board F3 Replace HV LV Board F4 Replace HV LV Board F5 ...

Page 5: ...ater NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechanical timers 1 At end of the cycl...

Page 6: ...BU VIOLET VT BLACK BK BROWN BR PINK PK GRAY GY WHITE WH MON FUSE BK BK BR BK OVEN LIGHT NOT ON ALL MODELS BK WH LOWER ANTENNA MOTOR WH BU RD 15 WH 26 BU 29 OR 7 WH 28 OVEN THERMAL LINK TOROID TOROID POWER CORD A B C D TERM BLK WH 28 BU BR BU LINE FILTER BK LINE LOAD L1 L1 L2 L2 BR BU BU BR CL BK CL GN YL WH 1 MON FUSE A B C D TERM BLK LINE FILTER LINE L1 L2 L1 LOAD L2 BLOWER MOTOR NO NC OR 9 WH 3 ...

Page 7: ...BLOWER MOTOR COM POWER AUX CONTROL BOARD MONITOR SWITCH MAGNETRON 1 TOP MAGNETRON 2 BOTTOM BOT MAG TCO POWER TRANSFORMER 230 M OVEN LIGHT NOT ON ALL MODELS M INTERLOCK SWITCH SECONDARY LOWER ANTENNA MOTOR UPPER ANTENNA MOTOR UPPER ANTENNA MOTOR TOP MAG TCO 20A FUSE LINE FILTER INTERLOCK SWITCH PRIMARY OVEN THERMAL LINK POWER CORD RECTIFIER C C C NO SECONDARY DOOR CLOSED INTERLOCK SWITCH SCHEMATIC ...

Reviews: