background image

Component Specifications 

 

!

WARNING

 

 

To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor  

 

before servicing, unless testing requires power. 

16500051 

 

January 2013 

  

©2013 ACP, Inc. 

2

 

Illustration 

Component 

Testing  

Results 

 

 

Thermal Cutout 

Disconnect all wires from TCO. 
Measure resistance across terminals. 
    Cavity Thermal Fuse ...................................
    Magnetron TCO ..........................................

 
 
Open at 104° C (219° F). 
Open at 138° C (280° F) and  

closed at 82° C (180° F). 

 

1400,1800 & 2100 
Watt units 

 

Diode Assembly 

Discharge Capacitors

 

 
Remove diode lead from capacitor and 
connect ohmmeter. 
 
Reverse leads for second test. 

Infinite resistance should be 
measured in one direction and 50K

 

or more in the opposite direction. 
 

NOTE:

 Analog meter must contain a 

battery of 6 volts minimum. 

MT2

MT1

GA TE

 

Triac 

Disconnect wires to triac. 
 
Measure resistance from: 
MT1 to MT2 ....................................................
MT1 to Gate ....................................................
MT2 to Gate ....................................................
All terminals to ground ....................................

Caution - Do not operate oven 
when wire to terminal MT2 is 
removed.

 

Infinite. 
Approximately 40 

 or more. 

Infinite. 
Infinite. 

 

Capacitor 

Discharge Capacitors

 

 
Remove wires from capacitor terminals and 
connect ohmmeter, set on highest 
resistance scale to terminals. 
 
 
 
Also check between each terminal and 
capacitor case. 

 
 

Between Terminals:

 Meter should 

momentarily deflect towards zero 
then return to over 5 M

. If no 

deflection occurs, or if continuous 
deflection occurs, replace capacitor. 
 

Terminal to Case:

 Infinite 

resistance. 

 

Snubber Assembly 

Disconnect wires to snubber. 
 
Measure resistance across terminals..............

 
 
Infinite. 

 

Magnetron 

Discharge Capacitors

 

 
Remove wires from magnetron and connect 
ohmmeter to terminals. Also check 
between each terminal and ground. 

Between Terminals:

 Less than 1 

 
Each terminal to ground measures 
Infinite resistance. 

NOTE:

 This test is not conclusive. If 

oven does not heat and all other 
components test good, replace the 
magnetron and retest. 

 

Blower Motor 

Remove all wires from motor. 
 
Measure resistance across coil .......................

 
 
Approximately 30 

Earth

Load

Line

 

Line filter 

Line to Line .....................................................
Load to Load ...................................................
Line to Load ....................................................
Any terminal to Earth ......................................

.8 M

.

 

.8 M

.

 

Continuity. 
Infinite. 

Wire Harness 

 

Test continuity of wires ................................... Continuity. 

Summary of Contents for P2002228M

Page 1: ...risk of electrical shock personal injury or death disconnect power to oven and discharge capacitor before servicing unless testing requires power Models DEC14E2A DEC18E2A Power Source Voltage AC 230 VAC 230 VAC Amperage single unit 16 A 16 A Frequency 50 Hz 50 Hz Single phase 3 wire earthed X X Power Output Nominal microwave energy IEC705 1400 Watts 1800 Watts Minimum temperature rise T 14ºF 7 5ºC...

Page 2: ...ed Infinite Approximately 40 Ω or more Infinite Infinite Capacitor Discharge Capacitors Remove wires from capacitor terminals and connect ohmmeter set on highest resistance scale to terminals Also check between each terminal and capacitor case Between Terminals Meter should momentarily deflect towards zero then return to over 5 MΩ If no deflection occurs or if continuous deflection occurs replace ...

Page 3: ...tely 12 KΩ Primary Logic Secondary Monitor Interlock switch assembly Disconnect wires to switch With door open measure resistance from Terminal C to NO Primary Terminal C to NO Secondary Terminal C to NC Monitor With door closed measure resistance from Terminal C to NO Primary Terminal C to NO Secondary Terminal C to NC Monitor Door Closed Primary Logic C NC NO C C NO Secondary Monitor Infinite In...

Page 4: ...otor antenna motor s and oven light Control board Terminals J4 1 J2 2 Cook relay Control board Terminals E1 E4 Line voltage All Conditions 0 VAC Idle and Standby 0 9 VAC Cook Line voltage Idle 0 VAC Standby and Cook Line voltage Idle 0 volts Standby and Cook Error Code Table Error Code Corrective Action F1 Replace HV LV Board F2 Replace HV LV Board F3 Replace HV LV Board F4 Replace HV LV Board F5 ...

Page 5: ...ater NOTE Water temperature should be approximately 60 F 16 C 2 Using the thermometer stir water for five to ten seconds measure and record the temperature T1 3 Place test container of water in the center of oven cavity and close door 4 Heat the water for a 33 second full power cycle NOTE Use a digital watch or a watch with a second hand for ovens with electromechanical timers 1 At end of the cycl...

Page 6: ...BU VIOLET VT BLACK BK BROWN BR PINK PK GRAY GY WHITE WH MON FUSE BK BK BR BK OVEN LIGHT NOT ON ALL MODELS BK WH LOWER ANTENNA MOTOR WH BU RD 15 WH 26 BU 29 OR 7 WH 28 OVEN THERMAL LINK TOROID TOROID POWER CORD A B C D TERM BLK WH 28 BU BR BU LINE FILTER BK LINE LOAD L1 L1 L2 L2 BR BU BU BR CL BK CL GN YL WH 1 MON FUSE A B C D TERM BLK LINE FILTER LINE L1 L2 L1 LOAD L2 BLOWER MOTOR NO NC OR 9 WH 3 ...

Page 7: ...BLOWER MOTOR COM POWER AUX CONTROL BOARD MONITOR SWITCH MAGNETRON 1 TOP MAGNETRON 2 BOTTOM BOT MAG TCO POWER TRANSFORMER 230 M OVEN LIGHT NOT ON ALL MODELS M INTERLOCK SWITCH SECONDARY LOWER ANTENNA MOTOR UPPER ANTENNA MOTOR UPPER ANTENNA MOTOR TOP MAG TCO 20A FUSE LINE FILTER INTERLOCK SWITCH PRIMARY OVEN THERMAL LINK POWER CORD RECTIFIER C C C NO SECONDARY DOOR CLOSED INTERLOCK SWITCH SCHEMATIC ...