Component Specifications
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
January 2013
16500051
©2013 ACP, Inc.
3
Illustration
Component
Testing
Results
COM
230
4
7
6
5
8
Transformer
#
4
#
1
#
2
#
5
#
6
#
7
#
8
Discharge Capacitor
Remove all wires from terminals, and
measure resistance from:
230 to Common ...............................................
Terminal 5 to 6 ................................................
Terminal 7 to 8 ................................................
Terminal 4 to Earth screw on transformer .......
Terminal 4 to any other terminal ......................
1
Ω
.
<1
Ω
.
<1
Ω
.
70
Ω
.
Infinite resistance. If not, replace
transformer.
Stirrer motor
230 VAC
Remove all wires from motor.
Measure resistance across terminals ................
Approximately 12 K
Ω
.
Primary /
Logic
Secondary
Mo nitor
Interlock switch
assembly
Disconnect wires to switch.
With door open measure resistance from:
Terminal C to NO Primary ..........................
Terminal C to NO Secondary .....................
Terminal C to NC Monitor ...........................
With door closed measure resistance from:
Terminal C to NO Primary ..........................
Terminal C to NO Secondary .....................
Terminal C to NC Monitor ...........................
Door Closed
Primary / Logic C
NC
NO
C
C
NO
Secondary
Monitor
Infinite.
Infinite.
Continuity.
Continuity.
Continuity.
Infinite.
Touch Panel
Assembly
Continuity is indicated as 100
Ω
and below.
Pin 1:
Ground.
1
2
3
4
5
6
7
8
9
Split
10
Pad
1
2
3
4
5
6
7
8
9
0
Start
Stop/Reset
Power Level
X 2
Time Entry
Trace
8 & 10
7 & 10
6 & 10
5 & 10
4 & 10
3 & 10
8 & 9
7 & 9
6 & 9
5 & 9
4 & 9
4 & 8
5 & 8
6 & 8
7 & 8
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity