ARX2 / MRX2 Estimated Heat Load Calculations
ARX2/MRX2 (single phase)
Parameters
Operating Time
12 Hours
Energy Costs
$0.11 KWHr
Idle Time
2 Hours
Cook Cycles/Daily
100
Typical Cook Time
60 Seconds
Data
Time
(Minutes)
Power
(Watts)
kWh
Cost/Day
Balance of
Time
(Hours)
Warm Up
8.6
3,150
0.5
$0.05
11.86
Cooking
100
4,953
8.3
$0.91
10.19
Idle Time
611.4
768
7.8
$0.86
0.00
TOTAL COST PER DAY $1.82
TOTAL COST PER MONTH $54.55
TOTAL COST PER YEAR $654.65
HVAC Requirements per Operating Time (Estimated)
Average
Energy
Cooking
and Idle
Warm-Up
Energy
Total
Energy
Total
Average
Power
Total
Environmental
Load
Average
Cooling
Requirement
57,892 kJ
1,622 kJ
59,514 kJ
1,378 W
4,700 Btu/hr
0.39 Tons of
AC