WARRANTY INFORMATION

Acorn warrants that all of its products are guaranteed against defective material or poor workmanship for a period of 
one year from date of shipment. Acorn's liability under this warranty shall be discharged by replacing without charge 
F.O.B. City of Industry, California, any goods, or part thereof, which appears to the company upon inspection to be of 
defective  material  or  not  of  first  class  workmanship,  provided  that  claim  is  made  in  writing  to  the  company  within 
reasonable period after receipt of the product. Where claims for defects are made, the defective part or parts shall be 
delivered to the company, prepaid, at City of Industry, California for inspection. Acorn will not be liable for the cost of 
repairs, alterations or replacement, or for any expense connected therewith made by the owner or his agents, except 
upon  written  authority  from  the  Acorn  City  of  Industry  office.  Acorn  will  not  be  liable  for  any  damages  caused  by 
defective  materials  or  poor  workmanship,  except  for  replacements,  as  above  provided.  Contact  local  Acorn 
Representative for complete terms and conditions.

M A I L  A D D R E S S 

P. O .  B O X  3 5 2 7  

C I T Y  O F  I N D U S T R Y,  C A  9 1 7 4 4  U . S . A .

P H Y S I C A L  A D D R E S S 

1 5 1 2 5  P R O C T O R  AV E N U E  

C I T Y  O F  I N D U S T R Y,  C A  9 1 7 4 6  U . S . A .

T O L L  F R E E

  8 0 0 - 4 8 8 - 8 9 9 9  • 

L O C A

L  6 2 6 - 3 3 6 - 4 5 6 1

FA X

  6 2 6 - 9 6 1 - 2 2 0 0  • 

W E B

  w w w. a c o r n e n g . c o m 

ACORN ENGINEERING FIELD SERVICE

TOLL FREE

 800-743-8259 • 

LOCAL

  626-855-4866 • 

FAX

 626-855-4863

Date: 01/10/17

Page 22 of 22

MERIDIAN 3802

Part #: 6216-011-000

Summary of Contents for MERIDIAN 3802

Page 1: ...nd Anchoring Hardware and Appropriate Tools 9 32 10 Count Fixture Wall Anchors and Anchoring Hardware and Appropriate Tools INSTALLATION OPERATIONS MAINTENANCE MANUAL Please visit www acorneng com for...

Page 2: ...is 130 F 54 4 C Maximum outlet temperature is recommended is 105 F 40 6 C Valve assembly must be drained prior to being subjected to freezing temperatures A checkstop is provided with this valve assem...

Page 3: ...for most current specifications MERIDIAN 3802 ACCESSIBILITY COMPARISONS ADA ages 6 thru 12 ADA Adult OBC Ontario Building Code 131 8 22 33 4 34 RIM MAX 27 17 9 131 8 22 33 4 31 RIM MAX 27 17 9 131 8 2...

Page 4: ...E 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 INSTALLATION OPERATIONS MAINTENANCE MANUAL Please visit www acorneng com for most current specifications DIMENSIONAL DATA MERIDIAN 3802 56 22 17 Date...

Page 5: ...ngle Bracket Mounting Slots 8 Places G Wall Anchoring 9 32 x 3 4 Long Enclosure Mounting Slots 9 Places 9 16 Mounting Hole Support Bracket Mounting 2 Places I Wall Anchoring 3 8 x 3 4 Long Trap Cover...

Page 6: ...advantageous to install to the deck faucets soap dispensers or other accessories prior to wall mounting Hang deck and trap enclosure onto mounting bracket level 3and mount to the finished wall using 1...

Page 7: ...1 1 2 16 UNE Threads 2 Rubber Gasket Flat Fiber Washer 1 1 2 16 UNI Rough Chrome Brass Jam Nut 1 1 2 16 x 1 1 4 UNI Close Ell with 3 8 NPT Clean Out Plug WASTE PLUMBING Assemble waste piping using te...

Page 8: ...s the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting 1 Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure...

Page 9: ...r supplies If any leaks are observed hand tighten connections as necessary to stop leaks before proceeding 5 Turn on fixture and allow water to flow for 2 minutes Measure water temperature at outlet I...

Page 10: ...2 Connect power supply to sensor Red light should be flashing 3 Move hand in front of sensor to distance of 2 to 4 within 5 seconds and wait until red light flashes quickly 4 Move hand to desired sens...

Page 11: ...1 4 Min Ferrule Nut H Hand Operated 1 8 O D AIR TUBE 1 4 O D WATER LINE Leave a minimum 1 4 of polyethylene tubing through the Ferrule Nut on the pushbutton assembly This is necessary to ensure prope...

Page 12: ...nting brackets provided as shown Wall anchors and anchoring hardware provided by installer A Install soap filler assembly to deck as shown B Attach 1 1 4 O D refill tube to soap filler assembly and so...

Page 13: ...ng com for most current specifications MERIDIAN 3802 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 MODEL 3802 AB09 SOS MODEL 3802 AB09 PDM FINISHED LAYOUTS...

Page 14: ...neng com for most current specifications MERIDIAN 3802 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 FINISHED LAYOUTS SHOWN FOR REFERENCE MODEL 3802 H PDM...

Page 15: ...lenoid assembly Remove solenoid pull out plunger and spring and clean with scale remover solution or pressurized air Debris or scale in diaphragm Remove diaphragm and clean Sensor flashes once when us...

Page 16: ...d Replace servomotor timer assembly Probable Cause Solution Valve riser tubing is crimped Straighten valve riser tubing Debris or scale in checkstop strainer Remove checkstop strainer and clean Blocka...

Page 17: ...t a scratch Standard Satin Finish Only Use of synthetic abrasive general purpose pads such as Scotch Brite is recommended Apply the stainless steel cleaner polish to the synthetic abrasive pads and CA...

Page 18: ...nder Washer COMPONENTS REPAIR PARTS Description Part No Diagram MOUNTING HARDWARE 0337 050 000 1 4 Stainless Steel Helical Lock Washer Stern Easy E B Sensor Operated Spout 9VDC 2993 400 001 SPOUTS Ste...

Page 19: ...t Diagram Push Button Assembly Dyson Airblade Tap Short Deck Mounted Faucet 3040 085 000 2566 270 001 9 VDC Plug In Transformer 0711 410 001 9 VDC Solenoid 2563 326 001 Stern Easy E Adapter Kit 6215 1...

Page 20: ...iption Part No Diagram ENCLOSURES Grid Strainer w Close Elbow 4926 062 001 ELECTRIC HARDWARE CONTINUED P Trap Waste Assembly 4970 040 003 Mounting Bracket 3803 Mounting Bracket 6216 204 199 WASTE ASSE...

Page 21: ...ALVE Diagram Optional 2 Station Hand Operated Single Temp Metering Valve Assembly Optional 2 Station 9VDC Solenoid Single Temp Valve Assembly Optional T P 2 Station Hand Operated ASSE 1016 Mixing Valv...

Page 22: ...ve part or parts shall be delivered to the company prepaid at City of Industry California for inspection Acorn will not be liable for the cost of repairs alterations or replacement or for any expense...

Reviews: