Important:  Some  options  may  slightly  alter  installation. To  ensure  proper  installation 
review the manual thoroughly and verify rough-ins before beginning any work. File this 
manual with the owner or maintenance personnel upon completion of installation.

Industry standard wall backing, for wall hung fixtures, is required. Installer provided wall 
anchors and wall anchoring hardware must be appropriate for wall construction, and 
have a minimum pull-out rating of 1000 lbs. (453.6 kg).

ANSI, UFAS or ADA compliance is subject to the interpretation and requirements of the 
local code authority and is the responsibility of the installer for verification.

Single Temp Valve Assembly: Recommended working water pressure is 30 psi (2.07 
bars)  minimum  to  100  psi  (6.89  bars)  maximum.  Maximum  temperature  is  130°F 
(54.4°C).  Maximum  outlet  temperature  is  recommended  is  105°F  (40.6°C).  Valve 
assembly  must  be  drained  prior  to  being  subjected  to  freezing  temperatures.  A 
checkstop is provided with this valve assembly.

T/P Mixing Valve Assembly: Recommended working water pressure is 30 psi (2.07 bars) 
minimum to 100 psi (6.89 bars) maximum. Maximum hot water temperature is 180°F 
(82°C). Temperature adjustment range is 95-110°F (43-48°C). Valve assembly must be 
drained prior to being subjected to freezing temperatures. The valve assembly has a 
check integral to the inlet however, angle stop is to be provided by the installer.

Prior to installation, supply lines must be flushed of all foreign material such as pipe 
dope, chips, or solder. Debris or foreign material in water supply may damage valve.

Teflon tape is recommended on all threaded waste and supply connections to reduce the 
possibility of leaks.

Provide  110-120VAC/60Hz/3A  (MAX)  electrical  receptacle  for  factory  supplied 
120VAC/9VDC, 100mA plug-in transformer. 

NOTE: Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth 
grounded per N.E.C. (National Electrical Code). 

MERIDIAN 3802

Date: 01/10/17

Page 22 of 22

Part #: 6216-011-000

Summary of Contents for MERIDIAN 3802

Page 1: ...nd Anchoring Hardware and Appropriate Tools 9 32 10 Count Fixture Wall Anchors and Anchoring Hardware and Appropriate Tools INSTALLATION OPERATIONS MAINTENANCE MANUAL Please visit www acorneng com for...

Page 2: ...is 130 F 54 4 C Maximum outlet temperature is recommended is 105 F 40 6 C Valve assembly must be drained prior to being subjected to freezing temperatures A checkstop is provided with this valve assem...

Page 3: ...for most current specifications MERIDIAN 3802 ACCESSIBILITY COMPARISONS ADA ages 6 thru 12 ADA Adult OBC Ontario Building Code 131 8 22 33 4 34 RIM MAX 27 17 9 131 8 22 33 4 31 RIM MAX 27 17 9 131 8 2...

Page 4: ...E 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 INSTALLATION OPERATIONS MAINTENANCE MANUAL Please visit www acorneng com for most current specifications DIMENSIONAL DATA MERIDIAN 3802 56 22 17 Date...

Page 5: ...ngle Bracket Mounting Slots 8 Places G Wall Anchoring 9 32 x 3 4 Long Enclosure Mounting Slots 9 Places 9 16 Mounting Hole Support Bracket Mounting 2 Places I Wall Anchoring 3 8 x 3 4 Long Trap Cover...

Page 6: ...advantageous to install to the deck faucets soap dispensers or other accessories prior to wall mounting Hang deck and trap enclosure onto mounting bracket level 3and mount to the finished wall using 1...

Page 7: ...1 1 2 16 UNE Threads 2 Rubber Gasket Flat Fiber Washer 1 1 2 16 UNI Rough Chrome Brass Jam Nut 1 1 2 16 x 1 1 4 UNI Close Ell with 3 8 NPT Clean Out Plug WASTE PLUMBING Assemble waste piping using te...

Page 8: ...s the push in fitting body and hold While holding the collet in pull on the PE tubing to remove from the push in fitting 1 Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure...

Page 9: ...r supplies If any leaks are observed hand tighten connections as necessary to stop leaks before proceeding 5 Turn on fixture and allow water to flow for 2 minutes Measure water temperature at outlet I...

Page 10: ...2 Connect power supply to sensor Red light should be flashing 3 Move hand in front of sensor to distance of 2 to 4 within 5 seconds and wait until red light flashes quickly 4 Move hand to desired sens...

Page 11: ...1 4 Min Ferrule Nut H Hand Operated 1 8 O D AIR TUBE 1 4 O D WATER LINE Leave a minimum 1 4 of polyethylene tubing through the Ferrule Nut on the pushbutton assembly This is necessary to ensure prope...

Page 12: ...nting brackets provided as shown Wall anchors and anchoring hardware provided by installer A Install soap filler assembly to deck as shown B Attach 1 1 4 O D refill tube to soap filler assembly and so...

Page 13: ...ng com for most current specifications MERIDIAN 3802 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 MODEL 3802 AB09 SOS MODEL 3802 AB09 PDM FINISHED LAYOUTS...

Page 14: ...neng com for most current specifications MERIDIAN 3802 ACORN ENGINEERING FIELD SERVICE TOLL FREE 800 743 8259 LOCAL 626 855 4866 FAX 626 855 4863 FINISHED LAYOUTS SHOWN FOR REFERENCE MODEL 3802 H PDM...

Page 15: ...lenoid assembly Remove solenoid pull out plunger and spring and clean with scale remover solution or pressurized air Debris or scale in diaphragm Remove diaphragm and clean Sensor flashes once when us...

Page 16: ...d Replace servomotor timer assembly Probable Cause Solution Valve riser tubing is crimped Straighten valve riser tubing Debris or scale in checkstop strainer Remove checkstop strainer and clean Blocka...

Page 17: ...t a scratch Standard Satin Finish Only Use of synthetic abrasive general purpose pads such as Scotch Brite is recommended Apply the stainless steel cleaner polish to the synthetic abrasive pads and CA...

Page 18: ...nder Washer COMPONENTS REPAIR PARTS Description Part No Diagram MOUNTING HARDWARE 0337 050 000 1 4 Stainless Steel Helical Lock Washer Stern Easy E B Sensor Operated Spout 9VDC 2993 400 001 SPOUTS Ste...

Page 19: ...t Diagram Push Button Assembly Dyson Airblade Tap Short Deck Mounted Faucet 3040 085 000 2566 270 001 9 VDC Plug In Transformer 0711 410 001 9 VDC Solenoid 2563 326 001 Stern Easy E Adapter Kit 6215 1...

Page 20: ...iption Part No Diagram ENCLOSURES Grid Strainer w Close Elbow 4926 062 001 ELECTRIC HARDWARE CONTINUED P Trap Waste Assembly 4970 040 003 Mounting Bracket 3803 Mounting Bracket 6216 204 199 WASTE ASSE...

Page 21: ...ALVE Diagram Optional 2 Station Hand Operated Single Temp Metering Valve Assembly Optional 2 Station 9VDC Solenoid Single Temp Valve Assembly Optional T P 2 Station Hand Operated ASSE 1016 Mixing Valv...

Page 22: ...ve part or parts shall be delivered to the company prepaid at City of Industry California for inspection Acorn will not be liable for the cost of repairs alterations or replacement or for any expense...