ACORN ENGINEERING FIELD SERVICE
TOLL FREE
800-743-8259 •
LOCAL
626-855-4866 •
FAX
626-855-4863
INSTALLATION, OPERATIONS & MAINTENANCE MANUAL
®
MERIDIAN 3792
Please visit
www.acorneng.com
for most current specifications.
-DV SOAP OPTION RETRO-FIT & INSTALLATION
Part #: 9927-142-001
Remove Access Plug
Remove Corterra Plug
Install Soap Dispenser
Install Soap Filler
NOTE: Soap Tank Capacity = 1 Gallon
Do not exceed the capacity of the soap tank. Overfilling may result in spilling and pooling of soap
solution within the sprayhead enclosure and outside the soap tank.
Some soaps contain corrosive additives that can cause rust in soap dispensers.
Acorn Engineering Company recommends user/ maintenance personnel review
MSDS reports of soap and possible corrosive additives noted.
!
WARNING
Remove top cover from
1
unit. To remove cover, use
Allen head bit provided and
unscrew 10-32 x 3/4" long
vandal resistant fasteners
shown. Hex bit driver is
installer provided.
Remove Corterra plug from
2
top cover and soap access
plug from bottom of
sprayhead enclosure.
Position and install soap
3
tank in sprayhead
enclosure as shown and
install soap dispenser by
aligning dispenser with
drain adapter and fixing
with set screws as shown
Install soap filler assembly
4
to top cover and replace.
Fill soap tank by removing
5
filler cap and pouring soap
directly into tank. Do NOT
overfill.
Install Soap Tank
Sprayhead
Enclosure
Page 16 of 31
Revised: 03/07/19