Acorn Engineering SFST-T-OT-ITG Installation, Operation And Maintenance Instructions Download Page 5

 

Page 5 of 8

1. Locate mixing valve fixture in a suitable place

accessible for servicing and adjusting. Valve
fixture should be as close as possible to point
of use. 

2. Thoroughly flush supplies. 
3. Connect Hot and Cold supplies to mixing valve

inlets and outlet to fixture(s). Valve fixture
connections are 1/2” NCT, for supply lines
by others.

4. Turn on supplies and inspect for leaks. Tighten

connections if leak(s) are detected.

5. Turn on fixture and allow to run until water

temperature stabilizes. Measure water
temperature. If water is not at desired
temperature adjust as needed, (refer to
adjustment section below). Maximum
recommended outlet temperature is 115°F
(46°C). 

1. Loosen locknut. 

Detail A

2. Turn on fixture so temperature can stabilize.
3. Using 1/4” allen wrench turn adjustment stem

counter-clockwise for hotter or clockwise for
colder outlet temperature. 

Detail B

 

4. Tighten locknut to prevent any unauthorized

or accidental temperature adjustment.

5. Re-check temperature.

INSTALLATION:

TEMPERATURE ADJUSTMENT:

Acorn Controls 

Division of Acorn Engineering Company

®

, A member of Morris Group International

SFST Installation & Operation Manual

DETAIL A

DETAIL B

LOCKNUT

5/8" WRENCH

1/8" ALLEN

WRENCH

ADJUSTMENT

STEM

TYPICAL INSTALLATION

INSTALLER 

PROVIDED

1/2” NCT RISER,

SUPPLIES AND

CONNECTIONS

Manual #7802-117-000

Date: 09/22/17

Summary of Contents for SFST-T-OT-ITG

Page 1: ...to materials which have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the...

Page 2: ...ture does not exceed 115 F 46 C after installation maintenance or repair Not provided by Acorn 1 Wall anchors screws nuts and washers as required 2 Lead free solder and flux for sealing water connecti...

Page 3: ...f Acorn Engineering Company A member of Morris Group International SFST Installation Operation Manual SFST T OT ITG SFST B OB ITG SFST B OT ITG SFST B OSL ITG 127 8 327 13 330 73 4 197 105 8 270 13 33...

Page 4: ...mber of Morris Group International SFST Installation Operation Manual 41 4 108 16 406 73 4 197 73 4 197 16 406 73 4 197 73 4 197 131 2 343 105 8 270 13 4 44 8 203 145 8 371 131 2 343 73 4 197 73 4 197...

Page 5: ...djust as needed refer to adjustment section below Maximum recommended outlet temperature is 115 F 46 C 1 Loosen locknut Detail A 2 Turn on fixture so temperature can stabilize 3 Using 1 4 allen wrench...

Page 6: ...FROM VALVE HOT OR COLD SUPPLY FAILURE OR SHUTOFFS CLOSED OPEN SHUTOFFS OR RESTORE HOT AND COLD SUPPLIES CHECK VALVE FILTERS BLOCKED WITH DEBRIS CLEAN CHECK VALVES AND FILTERS COLD WATER SUPPLY TYPICA...

Page 7: ...ESSURE GAUGE CIRCULATOR FLOW DIRECTION C SELECT FLOW RATE NECESSARY TO ENSURE MIXING VALVE IS OPERATING AT AN ASSE 1017 MINIMUM CERTIFIED FLOW RATE SEE LITERATURE COLD WATER SUPPLY TYPICAL RECIRCULATI...

Page 8: ...FOR REFERENCE 15 ITEM DESCRIPTION ADJUSTMENT STEM LOCK NUT 5 VALVE BONNET 6 BONNET O RING 7 ADJUSTMENT STEM 8 ADJUSTMENT STEM O RING 9 SHUTTLE O RING 10 SHUTTLE 11 ITEM DESCRIPTION 12 THERMOSTATIC MO...

Reviews: