INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

 

 

 

SFST THERMOSTATIC MIXING VALVE SUPPLY FIXTURE

 

NOTES TO THE INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished.

2. Please read this entire booklet before beginning the installation.

3. Check your installation for compliance with plumbing and other applicable codes.

LIMITED WARRANTY

UNITED STATES AND CANADA

Acorn Controls warrants that its products are free from defects in material or workmanship under normal use and 
service for a period of one year from date of shipment. Acorn's liability under this warranty shall be discharged solely 
by replacement of repair of defective material, provided Acorn is notified in writing within one year from date of 
shipment, F.O.B. Industry, California.

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Acorn under this warranty. 
Acorn shall not be liable under any circumstances for incidental, consequential or direct charges caused by defects in 
materials, or any delay in the repair or replacement thereof. This warranty is in lieu of all other warranties expressed 
or implied. Product maintenance instructions are issued with each unit and disregard or non-compliance with these 
instructions will constitute an abnormal use condition and void the warranty.

FOR TECHNICAL ASSISTANCE

1.800.743.8259

[email protected]

Date: 09/22/17

 

Model SFST Series

Patent Pending

WWW.ACORNENG.COM

 

ACORN ENGINEERING COMPANY

P.O. BOX 3527
CITY OF INDUSTRY, CA 91744

UNITED STATES OF AMERICA

Acorn Controls 

Division of Acorn Engineering Company

®

, A member of Morris Group International

Federal
Public Law
111-380 
(No Lead)

Manual #7802-117-000

Summary of Contents for SFST-T-OT-ITG

Page 1: ...to materials which have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the...

Page 2: ...ture does not exceed 115 F 46 C after installation maintenance or repair Not provided by Acorn 1 Wall anchors screws nuts and washers as required 2 Lead free solder and flux for sealing water connecti...

Page 3: ...f Acorn Engineering Company A member of Morris Group International SFST Installation Operation Manual SFST T OT ITG SFST B OB ITG SFST B OT ITG SFST B OSL ITG 127 8 327 13 330 73 4 197 105 8 270 13 33...

Page 4: ...mber of Morris Group International SFST Installation Operation Manual 41 4 108 16 406 73 4 197 73 4 197 16 406 73 4 197 73 4 197 131 2 343 105 8 270 13 4 44 8 203 145 8 371 131 2 343 73 4 197 73 4 197...

Page 5: ...djust as needed refer to adjustment section below Maximum recommended outlet temperature is 115 F 46 C 1 Loosen locknut Detail A 2 Turn on fixture so temperature can stabilize 3 Using 1 4 allen wrench...

Page 6: ...FROM VALVE HOT OR COLD SUPPLY FAILURE OR SHUTOFFS CLOSED OPEN SHUTOFFS OR RESTORE HOT AND COLD SUPPLIES CHECK VALVE FILTERS BLOCKED WITH DEBRIS CLEAN CHECK VALVES AND FILTERS COLD WATER SUPPLY TYPICA...

Page 7: ...ESSURE GAUGE CIRCULATOR FLOW DIRECTION C SELECT FLOW RATE NECESSARY TO ENSURE MIXING VALVE IS OPERATING AT AN ASSE 1017 MINIMUM CERTIFIED FLOW RATE SEE LITERATURE COLD WATER SUPPLY TYPICAL RECIRCULATI...

Page 8: ...FOR REFERENCE 15 ITEM DESCRIPTION ADJUSTMENT STEM LOCK NUT 5 VALVE BONNET 6 BONNET O RING 7 ADJUSTMENT STEM 8 ADJUSTMENT STEM O RING 9 SHUTTLE O RING 10 SHUTTLE 11 ITEM DESCRIPTION 12 THERMOSTATIC MO...