User's Manual | ACOM 700S | 1.8-54 MHz Linear Amplifier
Page 22 of 52 | S e c t i o n FIRST POWER-ON, CONTROL SYSTEM, AND INITIAL CHECK
May 2021
Figure 3-2 Basic screen
The WARNING messages appear only temporarily (for about three seconds), afterwards the indication of
the operating values is restored automatically (see Section
4.4.a) The first protection level - WARNING
The SOFT FAULT messages appear in the same field but they remain on the screen until the AUTO OPERATE
time is elapsed (see Section
4.1.c AUTO OPERATE user setting
) or until the operator pushes any button, then
the operating values (regime measurands) indication is restored too.
c)
Working mode indicator - OPR, STB or AUTO OPER
4.1 Change of Modes RX/TX and Operate/Stand-by; AUTO OPERATE user setting
d)
RX/TX indicator
RX/TX indicator reads the request for transmit (KEY-IN input). The RX indication is green and the TX is red.
The indicator will flash frequently if switch over is impossible.
e)
Forward power bar graph and digital readout
Displays the forward power fed into the antenna.
f)
Reflected power bar graph and digital readout
Entering the red zone is not allowed.
g)
PA transistor temperature bar graph and readout
Entering the red zone is not allowed.
d
c
b
g
e
a
f
i
h
1
2