background image

13

D

 

512 so that the units can receive DMX signal. 

Press the 

MENU

 button up to when the 

DMX Address

 is showing on the display. Pressing

 ENTER 

button and the display will blink. Use 

DOWN 

and 

UP

 button to change the DMX512 address. Once 

the address has been selected, press and keep 

ENTER

 button pressed up to when the display stops 

blinking or storing automatically 8 seconds later. To go back to the functions without any change 

press the

 MENU

 button again. If you use please refer to the following diagram to address your   

DMX512 channel for the first 4 units: 

Channel mode 

Unit 1 

Address 

Unit 2 

Address 

Unit 3 

Address 

Unit 4 

Address 

7 channels 

17 

22 

9 channels 

10 

19 

28 

10 channels 

11 

21 

31 

5.3 DMX Configuration 

Summary of Contents for NEBULA

Page 1: ......

Page 2: ... 2 Technical Specifications 3 3 Control Panel 4 4 How to set the fixture 5 4 1 Menu 5 5 Control by DMX 512 controller 12 5 1 DMX Connection 12 5 2 DMX Address Setting 12 5 3 DMX Configuration 13 6 Troubleshooting 15 7 Fixture Cleaning 16 ...

Page 3: ...t while operating as it is fire hazard Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base Maximum ambient temperature is Ta 0 40 Unit surface temperature may reach up to 60 DO NOT touch the housing bare hand during its operation Turn off the power and allow about 15 minutes for the unit to cool down before replacing or serving In the ...

Page 4: ...his fixture is kept at least 0 5m away from any flammable materials decoration etc Always use and install the supplied safety cable as a safety measure to prevent accidental damage and or injury in the event the clamp fails 1 Bolt each clamp to the Omega holder with screw and lock nut through the hole in the holder 2 Faster the omega holders on the bottom of the base by inserting quick lock fasten...

Page 5: ...m 10 3Kg 12 2 x8 6 x17 8 in 22 7lbs 3 Control Panel 1 Monitor Batter Back up display 2 Button MENU To enter into move backward or leave the menu UP To go backward to move up in the menu DOWN To go to move down in the menu ENTER To perform the desired functions 3 Firmware Upgrade Frocedures for updating fixture ...

Page 6: ...e MENU button up to when the required one is showing on the display Select the function by the ENTER button and the display will blink Use the DOWN and UP button to change the mode Once the required mode has been selected press the ENTER button to setup to go back to the functions without any change press the MENU button again Hold and press the MENU button about one second or wait for one minute ...

Page 7: ...6D ...

Page 8: ...ute to exit menu mode View DMX Value To select View DMX Value press the ENTER button to show the VIEW DMX VALUE on the display Use the UP DOWN button to view the DMX channel values Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode Fixture Setting Enter MENU mode select Fixture Setting press the ENTER button to confirm use the UP DOWN button to select Pan...

Page 9: ... idle one minute to exit menu mode Dimmer Curve To select Dimmer Curve press the ENTER button to show the DIMMER CURVE on the display use the UP DOWN button to select Linear Square Law Inverse Squ or S curve Once selected press the ENTER button to store Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode Linear The increase in light intensity appears to be...

Page 10: ...lay goes off one minute after exiting menu mode Once selected press the ENTER button to confirm and store Press the MENU button back to the last menu or let the unit idle one minute to exit menu mode Backlight Intensity To select Backlight Intensity press the ENTER button to show the BACKLIGHT INTENSITY on the display Use the UP DOWN button to adjust the intensity from 1 dark to 10 bright Once sel...

Page 11: ...lue Once selected press the ENTER button to setup the fixture will run as the channel value indicates Press the MENU button back to the last menu or exit menu mode let the unit idle one minute All channels value will become 0 after exiting Manual Test menu Fixture Information Enter MENU mode select Fixture Information press the ENTER button to confirm use the UP DOWN button to select Fixture use t...

Page 12: ...utton to confirm use the UP DOWN button to select Factory Setting Factory Setting To select Factory Setting press the ENTER button to show the FACTORY SETTING on the display Press the ENTER button to confirm use the UP DOWN button to select No or Yes the fixture will reset to factory settings and exit menu mode RDM DMX START 0 512 MANUFAC TURER ACME DEVICE MODEL DESCRIPTION CM 250Z DMX PERSONALITY...

Page 13: ...e units power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor between pin 2 DMX and pin 3 DMX into a 3 pin XLR plug and plug it in the DMX output of the last fixture 4 Each lighting fixture needs to have an address set to receive the data sent by the controller The address number is between 0 511 usually ...

Page 14: ...cted press and keep ENTER button pressed up to when the display stops blinking or storing automatically 8 seconds later To go back to the functions without any change press the MENU button again If you use please refer to the following diagram to address your DMX512 channel for the first 4 units Channel mode Unit 1 Address Unit 2 Address Unit 3 Address Unit 4 Address 7 channels 1 8 17 22 9 channel...

Page 15: ...14D ...

Page 16: ...r easy troubleshooting A The unit does not work no light and the fan does not work 1 Check the connection of power and main fuse 2 Measure the mains voltage on the main connector 3 Check the power on LED B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors cables to see if link properly ...

Page 17: ... not working well 1 The stepper motor might be damaged or the cable connected to the PCB is broken 2 The motor s drive IC on the PCB might be out of condition 7 Fixture Cleaning The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or partic...

Page 18: ...17D ...

Page 19: ...18D ...

Page 20: ...in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 A1 2012 EN55103 2 2009 EN61000 3 2 2014 EN61000 3 3 2013 Harmonized Standard EN 60598 1 2015 EN 60598 2 17 1989 A2 1991 EN 62471 2008 EN 62493 2010 Safety of household and similar electrical appliances Part 1 General requirements ...

Reviews: