4D

 Start the address 

    How to address your DMX512 system: 

1. Select the channels of DMX controller 

2. Dipswitches   

Dip 

#1 

#2 

#3 

#4 

#5 

#6 

#7 

#8 

#9

 

Value  1 

16 

32 

64 

128 

256 

 Examples: 

Channel 01

dip / on : #1

=1

 

Channel 05

dip / on : #1, #3

1+4=5

 

Channel 09

dip / on : #1,#4

1+8=9

 

Channel 13

dip / on : #1,#3,#4

1+4+8=13

 

 

 

  A.   GENERAL INSTRUCTIONS                 

 

 

 

WARNING

 

 Please keep this booklet with the unit for future consultation. If you sell the unit to 

another user, be sure that the new user also receives this instruction booklet thus 

giving  them  the  necessary  information  about  the  use  and  general  warnings 

regarding the unit. 

  Before  the  initial  start-up,  please  unpack  and  carefully  check  all  components  in 

case any damage may have occurred during shipping. 

 Locate a suitable spot for your device where there is good ventilation. Also, make 

sure that no ventilating fans or slots are blocked. 

 Protect our environment! Please dispose of the packing boxes properly.   

  The  electrical  work  that  is  necessary  for  installation  must  done  by  qualified 

personnel. 

  Always  remember  to  unplug  the  unit  from  the  main  power  before  any  service  is 

done. Do not open the unit. There are no serviceable parts inside. 

 It is very important to ground the yellow/green conductor to earth in order to meet 

regulations for safety. 

 Check the surrounding area and make sure there are no flammable liquids, water or 

metal  objects  that  could  enter  the  fixture.  If  a  foreign  object  enters  the  unit, 

immediately disconnect the main power. Also, place the fixture in a well-ventilated 

room at about 15 cm from the walls. 

 Do not touch any wires during operation, as high voltage is hazardous. 

 In the event of serious operating problems, stop using the unit immediately. Never 

try to repair the unit yourself. Repairs carried out by unqualified personnel can lead 

to  damage  or  malfunction.  Please  contact  the  nearest  authorized  Technical 

Assistance Center. Always use genuine spare parts. 

Please read the enclosed instructions carefully as they include important 

points about safety for the installation, usage and maintenance of the unit. 

Summary of Contents for MH-635

Page 1: ... e Intelligent Scanner Professional Lighting Technology User Guide Please read the instructions carefully before use ...

Page 2: ...2D INDEX A GENERAL INSTRUCTIONS B MAIN FEATURES C LAMP D HOW TO CONTROL THE UNIT 1 By universal DMX controller 2 Preprogrammed function 3 By easy controller E FIXTURE CLEANING ...

Page 3: ...fore any service is done Do not open the unit There are no serviceable parts inside It is very important to ground the yellow green conductor to earth in order to meet regulations for safety Check the surrounding area and make sure there are no flammable liquids water or metal objects that could enter the fixture If a foreign object enters the unit immediately disconnect the main power Also place ...

Page 4: ...ogether as many as required in master slave mode and perform the great built in programmed lighting shows triggered by music Please use a 3 pin XLR cable plug when connecting them together It features different pre programmed chase patterns C LAMP Always switch off the mains supply and never handle the lamp or luminaire when it is hot Do not touch the bulb with bare hands If this does happen clean...

Page 5: ... signal cables y The DMX512 uses a very high speed signal Inadequate or damaged cables bad solder joints or corroded connectors can easily distort the signal and shut down the system A reliable DMX512 system starts with good quality cables y Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 The end of the DMX512 system sh...

Page 6: ...n any unit that is linking to the master unit to get contrast movement to the master unit even if you have two units only Dipswitch 10 on the first Master unit is no use for the 2 light show as it is the master unit that operates the light show 3 By easy controller The easy remote control is used only in master slave mode By connecting to the 1 4 microphone jack of the first unit its DMX input plu...

Page 7: ... DMX512 system 1 Select the channels of DMX controller 2 Dipswitches Dip 1 2 3 4 5 6 7 8 9 Value 1 2 4 8 16 32 64 128 256 Examples Channel 01 dip on 1 1 Channel 05 dip on 1 3 1 4 5 Channel 09 dip on 1 4 1 8 9 Channel 13 dip on 1 3 4 1 4 8 13 ...

Page 8: ...rts carefully y Clean the external optics at least once every 20 days Clean the internal optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000...

Page 9: ...0V 60Hz AC 230 250V 50Hz Fuse T5A T3 15A T6 3A T5A T6 3A T5A Lamps EFP 12V 100W ELC 24V 250W ELC 24V 250W Dimension 385x170x122mm 405x170x122mm 385x170x122mm Weight 3 8kg 4 5kg 4 5kg For further requirements contact the nearest authorized technical assistance office Широкий ассортимент оборудования ACME на www maxlight ru ...