 E.  FIXTURE   CLEANING                      

 

The cleaning of internal and  external optical  lenses  and/or  mirrors  must  be  carried 

out  periodically  to  optimize  light  output.  Cleaning  frequency  depends  on  the 

environment  in  which  the  fixture  operates:  damp,  smoky  or  particularly  dirty 

surroundings can cause greater accumulation of dirt on the unit’s optics. 

y

 

Clean with a soft cloth using normal glass cleaning products. 

y

 

Always dry the parts carefully. 

y

 

Clean the external optics at least once every 20 days. Clean the internal optics 

at least every 30/60 days. 

 

 

EC Declaration of Conformity 

 

We declare that our products (lighting equipments) comply with the 

following specification and bears CE mark in accordance with the 

provision of the Electromagnetic Compatibility (EMC) Directive 

89/336/EEC. 

 

EN55014-2: 1997 A1:2001, EN61000-4-2: 1995; EN61000-4-3:2002; 

EN61000-4-4: 1995; EN61000-4-5: 1995, EN61000-4-6:1996, 

EN61000-4-11: 1994. 

Harmonized Standard 

 

EN60598-1: 2000+ALL:2000+A12:2002 

Safety of household and similar electrical appliances 

Part 1 : General requirements

 

 

 

 

 
 
 
 
 
INDEX 

 
 

A. GENERAL INSTRUCTIONS 
 
B. MAIN FEATURES 
 
C. LAMP 
 
D. HOW TO CONTROL THE UNIT 
    -----

(1) By universal DMX controller

 

    -----

(2) Preprogrammed function 

    -----

(3) By easy controller 

 
E. FIXTURE CLEANING

 

 

 

 

 

 

 

 

 

 

Summary of Contents for MH-635

Page 1: ... e Intelligent Scanner Professional Lighting Technology User Guide Please read the instructions carefully before use ...

Page 2: ...2D INDEX A GENERAL INSTRUCTIONS B MAIN FEATURES C LAMP D HOW TO CONTROL THE UNIT 1 By universal DMX controller 2 Preprogrammed function 3 By easy controller E FIXTURE CLEANING ...

Page 3: ...fore any service is done Do not open the unit There are no serviceable parts inside It is very important to ground the yellow green conductor to earth in order to meet regulations for safety Check the surrounding area and make sure there are no flammable liquids water or metal objects that could enter the fixture If a foreign object enters the unit immediately disconnect the main power Also place ...

Page 4: ...ogether as many as required in master slave mode and perform the great built in programmed lighting shows triggered by music Please use a 3 pin XLR cable plug when connecting them together It features different pre programmed chase patterns C LAMP Always switch off the mains supply and never handle the lamp or luminaire when it is hot Do not touch the bulb with bare hands If this does happen clean...

Page 5: ... signal cables y The DMX512 uses a very high speed signal Inadequate or damaged cables bad solder joints or corroded connectors can easily distort the signal and shut down the system A reliable DMX512 system starts with good quality cables y Each lighting unit needs to have an address set to receive the data sent by the controller The address number is between 0 511 The end of the DMX512 system sh...

Page 6: ...n any unit that is linking to the master unit to get contrast movement to the master unit even if you have two units only Dipswitch 10 on the first Master unit is no use for the 2 light show as it is the master unit that operates the light show 3 By easy controller The easy remote control is used only in master slave mode By connecting to the 1 4 microphone jack of the first unit its DMX input plu...

Page 7: ... DMX512 system 1 Select the channels of DMX controller 2 Dipswitches Dip 1 2 3 4 5 6 7 8 9 Value 1 2 4 8 16 32 64 128 256 Examples Channel 01 dip on 1 1 Channel 05 dip on 1 3 1 4 5 Channel 09 dip on 1 4 1 8 9 Channel 13 dip on 1 3 4 1 4 8 13 ...

Page 8: ...rts carefully y Clean the external optics at least once every 20 days Clean the internal optics at least every 30 60 days EC Declaration of Conformity We declare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000...

Page 9: ...0V 60Hz AC 230 250V 50Hz Fuse T5A T3 15A T6 3A T5A T6 3A T5A Lamps EFP 12V 100W ELC 24V 250W ELC 24V 250W Dimension 385x170x122mm 405x170x122mm 385x170x122mm Weight 3 8kg 4 5kg 4 5kg For further requirements contact the nearest authorized technical assistance office Широкий ассортимент оборудования ACME на www maxlight ru ...