background image

 
 

  7. Troubleshooting   

Following are a few common problems that may occur during operation. Here are some 

suggestions for easy troubleshooting: 

A. The fixture does not work, no light 

1.

 

Check the connection of power and main fuse. 

2.

 

Measure the mains voltage on the main connector. 

B. Not responding to DMX controller 

1.

 

DMX LED should be on. If not, check DMX connectors, cables to see if link properly. 

2.

 

If the DMX LED is on and no response to the channel, check the address settings and DMX 

polarity. 

3.

 

If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the 

fixture or the previous one. 

4.

 

Try to use another DMX controller.     

5.

 

Check if the DMX cables run near or run alongside to high voltage cables that may cause 

damage or interference to DMX interface circuit.   

C. One of the channels is not working well 

1.

 

The stepper motor might be damaged or the cable connected to the PCB is broken. 

2.

 

The motor’s drive IC on the PCB might be out of condition. 

 

 

  8. Fixture Cleaning   

Cleaning must be carried out periodically to optimize light output. Cleaning frequency depends on 

the environment in which the fixture operates: moist, smoky or particularly dirty surroundings can 

cause a greater accumulation of dirt on the fixture. 

 

Clean with soft cloth using normal glass cleaning fluid or mild soapy water. 

 

Always dry the parts carefully. 

 

Clean the external optics at least every 30 days. 

 

 

11 

Summary of Contents for LITE PANEL 900 LP-900 CW BD30

Page 1: ...LP 900 WW BD30 LP 900 CW BD30 User Manual Please read the instructions carefully before use...

Page 2: ...ifications 3 3 How To Set The Fixture 4 3 1 Control Panel 4 3 2 Main Function 5 4 How To Control The Unit 8 4 1 Master Slave Function 8 4 2 DMX Controller 9 5 DMX512 Configuration 9 6 DMX512 Connectio...

Page 3: ...close to the unit while operating as it is fire hazard Use safety cables when fixing this unit Maximum ambient temperature is Ta 40 degrees C DO NOT operate it where the temperature is higher than th...

Page 4: ...s weight Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture The equipment must be installed by professionals It must be fixed at a place where...

Page 5: ...000K CRI 82 Weight 6 2Kgs Dimension 371 x 328 x 111mm 3 How To Set The Fixture 3 1 Control Panel 1 Display Shows the various menus and the selected functions 2 Indicator LED DMX On DMX input present M...

Page 6: ...OWER OUT Connects to the next unit 8 POWER IN Connects to mains supply power 3 2 Main Function To select any of the given functions press the MENU button up to the required selection as shown on the d...

Page 7: ...6...

Page 8: ...button to setup or automatically exit menu mode without any change after 30 seconds To go back to the functions without any change press the MENU button Blackout Mode To select press the ENTER button...

Page 9: ...will show the number of working hours of the unit To go back to the functions press the MENU button Software Version To select press the ENTER button to show SOFTWARE VERSION on the display and the d...

Page 10: ...d the display will blink Use the DOWN UP buttons to change the DMX 512 address Once the address has been selected press and hold the ENTER button until the display stops blinking or it will store auto...

Page 11: ...gh to maintain the DMX circuit when one of the units power is disconnected 3 At last fixture the DMX cable has to be terminated with a terminator to reduce signal errors Solder a 120 ohm 1 4W resistor...

Page 12: ...previous one 4 Try to use another DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the...

Page 13: ...12...

Page 14: ...13...

Page 15: ...he provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 EN55103 2 2009 EN62471 2008 EN61000 3 2 2006 A1 2009 A2 2009 EN61000 3 3 2008 Harmonized Standard EN 60598 1 2...

Page 16: ...Innovation Quality Performance 15...

Reviews: