background image

 

                                                                                              LED-HC101  II 

                                                                                                                         

 

A. DMX address setting by dip-switches 

1. Set the start address by dip-switch as the diagram below

 

2. Hold the AUTO DMX ADDRESS button for about 5 seconds, the LED 

lights blinking indicating the address is set successfully. 

 

Dip 

# 1 

# 2 

# 3

# 4

# 5 

# 6 

# 7

# 8

# 9

# 10 

Value 

1 2 4 8 16 

32 

64

128

256

Master/Slave

 

 Examples: 

Channel 01

dip / on : # 1

=1

 

Channel 05

dip / on : # 1, # 3

1+4=5

 

Channel 09

dip / on : # 1, # 4 

1+8=9

 

Channel 13

dip / on : # 1, # 3, # 4

1+4+8=13

 

 

B. Auto DMX addressing   

1.  The DMX address of fixture can be set automatically. Set all dip-switches to OFF 

and hold the 

AUTO DMX ADDRESS

 button of the first unit for about 5 seconds, 

the fixture will be set the DMX start address to 1, and the other fixtures of the 

chain will be set their own DMX start address automatically. 

2.  The LED fixtures use four channels, the next fixture’s will be automatic calculate 

their own DMX address, not need to calculate the DMX channels of each fixture 

in the chain. (Fixture 1 = 1, Fixture 2 = 5, Fixture 3 = 9, Fixture 4 = 13, Fixture…) 

3.  No need to turn the fixture off when you change the DMX address, as new DMX 

address setting will be effect at once. Every time you turn the fixture on, it will be 

ready to receive DMX signal or run the built-in programs. 

 

 

 

 

 

 

                                                                                              LED-HC101  II 

                                                                                                                         

 

 

C. Remote DMX address setting by CA-T DMX TESTER 

The fixture can be set the DMX address remotely by CA-T 

DMX TESTER

. Please 

refer to the CA-T user manual to set the DMX address to the fixture. 

 

 

 

D. Remote DMX address setting by universal DMX controller 

y

 

Make sure the DMX cables of all units are connected. 

y

 

Connect the first unit to a universal DMX controller. 

y

 

Connect all units to the mains so they are switched on. 

y

 

Set all DMX-channels on your DMX-controller to zero (value 000). 

y

 

Set the DMX-channel, that you want to assign as DMX start address on you unit, 

to maximum (value 255). 

y

 

Press the “Auto DMX address” button on the unit shortly. 

y

 

If you want to set another unit to the same DMX start address, simply press it’s 

“Auto DMX address” button and it will receive the same address. 

y

 Done! 

An example to make things clear: 

y

 

We will set the DMX start address of a unit to 106: 

y

 

Connect the unit to the DMX-controller as described above and make sure all is 

switched on. 

y

 

Set all DMX-channels on the controller to zero (000). 

y

 

Now set DMX-channel 106 to maximum (255). 

y

 

Press the “Auto DMX address” button on the unit shortly. 

y

 

Done! Your unit now has DMX address 106! 

5A

6A

Summary of Contents for LED-HC101 II

Page 1: ...re operates damp smoky or particularly dirty surrounding can cause greater accumulation of dirt y Clean with soft cloth using normal glass cleaning fluid y Always dry the parts carefully y Clean the external at least every 20 days LED HC101 II User Manual Please read the instructions carefully before use Innovation Quality Performance 2014 05 10 毅丰 受控正本 ...

Page 2: ...ain connector B Not responding to DMX controller 1 DMX LED should be on If not check DMX connectors and cables to see if link properly 2 If the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the fixture or the previous one 4 Try to use another DMX controller 5 Check if...

Page 3: ...ative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal LED HC101 II 1 Safety Introductions WARNING y Please keep this User Manual for future consultation If you sell the fixture to another user be sure that they also receive this instruction booklet y Unpack and check carefully there is no transportation damage before using the fixture y Before operating...

Page 4: ...show the status of the unit 5 DIP SWITCH used to set the start address of the unit or choose functions 6 AUTO DMX ADDRESS used to set start address automatically 7 LED WD CONNECTOR used to receive the signal of LED WD only 8 SIGNAL OUTPUT output signal and power for light LED HC101 II C Master Slave operation The fixture will allow you to link 16 fixtures together and operate without a controller ...

Page 5: ...ng the LED fixture 2 Unscrew the screws and connect the wires as diagrams below 3 Tight the screws CAUTIONS the LED controller total output power consumption is 100 watt 5 DMX512 Address Setting Each fixture needs to have a start address set to receive the data sent by the controller The address number is between 0 511 usually 0 1 are equal to 1 The address also know as the start channel is the fi...

Page 6: ...at once Every time you turn the fixture on it will be ready to receive DMX signal or run the built in programs LED HC101 II C Remote DMX address setting by CA T DMX TESTER The fixture can be set the DMX address remotely by CA T DMX TESTER Please refer to the CA T user manual to set the DMX address to the fixture D Remote DMX address setting by universal DMX controller y Make sure the DMX cables of...

Reviews: