ACME LED-3082 RGB User Manual Download Page 7

 

9A 

5.2 Easy Controller (by CA-8) 

The  easy  remote  control  is  used  only  in  master/slave  mode.  By 

connecting to the 1/4” microphone jack of the first unit, you will find that 

the  remote  controller  on  the  first  unit  will  control  all  the  other  units  for 

Stand by, Function and Mode selection 

 

 

 

5.3 DMX Controller   

Using universal DMX controller to control the units, you have to set DMX address from 1 to 

512 channel so that the units can receive DMX signal. 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 

button and the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 address. 

Once the address has been selected, press and keep 

ENTER

 button pressed up to when 

the  display  stops  blinking  or  storing  automatically  8  seconds  later.  To  go  back  to  the 

functions without any change press the

 MENU

 button again. If you use please refer to the 

following diagram to address your DMX512 channel for the first 4 /2 units.   

1 channel mode:       

3 channels mode:

 

 

 

 

 

 

 

Blackout  Blackout the unit 

Function 

1. SynchroStrobe 
2. Asynchro Strobe 
3. Sound Strobe 

Select Show 
(Show 1-8) 

Select Speed 
1. Slow 
2. Middle 
3. Fast 

Mode 

Sound/Strobe 
(LED OFF)

 

Show 
(LED ON) 

LED blinking 

 

6A 

  Channel Mode 

Press the 

MENU

 button up to when the 

  is shown on the display. Pressing 

ENTER

 

button,  Use 

DOWN

  and 

UP

  button  to  select  the 

  (1  channel)  or 

  (3 

channels ) mode.

 

Once select, press the 

ENTER

 button to setup or automatically exit menu 

mode without any change after 30 seconds. To go back to the functions without any change 

press the 

MENU

 button

 

  Slave Mode 

Press the 

MENU

 button up to when the 

  is shown on the display. Pressing 

ENTER

 

button, Use 

DOWN

 and 

UP

 button to select the 

  (master) or 

  (slave 1) or 

  (Slave 2) mode.

 

Once select, press the 

ENTER

 button to setup or automatically exit 

menu mode without any change after 30 seconds. To go back to the functions without any 

change press the 

MENU

 button

 

  Show Mode 

Press the 

MENU

 button up to when the 

  is shown on the display. Pressing 

ENTER

 

button, Use 

DOWN

 and 

UP

 button to select the 

  (Random show) or 

  (show 

1)  or 

  (Show  2)  or  …  or 

  (show8).

 

Once  select,  press 

ENTER

  button  to 

store or automatically exit menu mode without any change after 30 seconds. To go back to 

the functions without any change press the 

MENU

 button

 

  Sound   

Press the 

MENU

 button up to when the 

  is shown on the display. Pressing 

ENTER

 

button, Use 

DOWN

 and 

UP

 button to select the 

  (sound on) or 

  (sound off).

 

Once  select,  press 

ENTER

  button  to  setup  or  automatically  exit  menu  mode  without  any 

change after 30 seconds. To go back to the functions without any change press the 

MENU

 

button

 

  Blackout mode 

Press the 

MENU

 button up to when the 

  is shown on the display. Pressing 

ENTER

 

button,  Use 

DOWN

  and 

UP

  button  to  select  the 

  (blackout)  or 

  (normal).

 

Once  select,  press 

ENTER

  button  to  setup  or  automatically  exit  menu  mode  without  any 

change after 30 seconds. To go back to the functions without any change press the 

MENU

 

Summary of Contents for LED-3082 RGB

Page 1: ...15A Innovation Quality Performance LED 3082 RGB LED 3084 RGB User Manual Please read the instructions carefully before use ...

Page 2: ...lare that our products lighting equipments comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN60598 1 2000 ALL 2000 A12 2002 Safety of household and s...

Page 3: ...top using the fixture immediately Never try to repair the fixture by yourself Repairs carried out by unskilled people can lead to damage or malfunction Please contact the nearest authorized technical assistance center Always use the same type spare parts Do not connect the device to any dimmer pack Do not touch any wire during operation and there might be a hazard of electric shock To prevent or r...

Page 4: ...ace where is out of the touch of people and has no one pass by or under it 12A 8 Troubleshooting Following are a few common problems that may occur during operation Here are some suggestions for easy troubleshooting A The fixture does not work no light 1 Check the connection of power and main fuse 2 Measure the mains voltage on the main connector B Not responding to DMX controller 1 DMX LED should...

Page 5: ...11 usually 0 1 are equal to 1 5 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin4 5 not used 4A 4 How toset the unit 4 1Rear Panel 1 Display To show the various menus and the selected functions LED 2 DMX On DMX input present 3 MASTER On Master Mode 4 SLAVE On Sla...

Page 6: ... change after idling 30 seconds Back to the functions without any change press MENU button The main functions are shown below DMX 512 Address Setting Press the MENU button up to when the is shown on the display Pressing ENTER button and the display will blink Use DOWN and UP button to change the DMX 512 address Once the address has been selected press ENTER button to setup or automatically exit me...

Page 7: ... Once select press the ENTER button to setup or automatically exit menu mode without any change after 30 seconds To go back to the functions without any change press the MENU button Slave Mode Press the MENU button up to when the is shown on the display Pressing ENTER button Use DOWN and UP button to select the master or slave 1 or Slave 2 mode Once select press the ENTER button to setup or automa...

Page 8: ...ton for about 5 seconds OPAN will shown on the display press ENTER button to confirm then use DOWN and UP button to adjust the home position 127 127 of the motor Once the position has been selected press the ENTER button to setup or exit the offset mode without any change press the MENU button 5 How To Control The Unit You can operate the unit in three ways 1 By master slave built in preprogram fu...