No need to turn the unit off when you change the DMX address, as new DMX address setting will 

be affect at once. Every time you turn the unit on, it will show “LED MB200R” on the display and 

move all the motors to their ‘home’ position and you may hear some noises for about 20 seconds. 

After that the unit will be ready to receive DMX signal or run the built in programs. 

 

4.1 Master/Slave Built In Preprogrammed Function   

By linking the units in master/slave connection, the first unit will control the other units to give an 

automatic, sound activated, synchronized light show. This function is good when you want an 

instant show. You have to set the first unit in master mode 

Show Mode

  and select 

show 0

  …… 

show 12

 mode. Its DMX input jack will have nothing plugged into it, and Its master LED will be 

constantly on and sound LED will flash to the music. The other units will have to set in 

slave mode

 

and select 

Slave 1

  (normal) or 

Slave 2

  (2 light show) mode, Their DMX cables plugged into the 

DMX input jacks (daisy chain) and the slave led lights will constantly on. 

2-light show 

In 

slave mode

Slave 1 

means the unit works normally and 

Slave 2

 means 2-light show. In order to 

create a great light show, you can set 

Slave 2

 on the second unit to get contrast movement to each 

other, even if you have two units only. 

 

4.2 DMX Controller   

By using a universal DMX controller to control the units, you will need to set DMX address from 1 

to 512 so that the units can receive DMX signal. 

Press the 

MENU

  button up to when the 

DMX  Address

  is showing on the display. Pressing the 

ENTER

 button and the display will blink. Use the 

DOWN

/

UP

 button to change the DMX512 address. 

Once the address has been selected, press the 

ENTER

 button to setup, to go back to the functions 

without any change press the

 MENU

 button again. Hold and press the 

MENU

 button about one 

second or wait for one minute to exit the menu mode.   

Please refer to the following diagram to address your DMX512 channel for the first 4 units

 

 

11A 

Summary of Contents for CB-16FC

Page 1: ...CB 16FC User Manual Please read the instruction carefully before use...

Page 2: ...ow To Set The Unit 4 3 1 Control Panel 4 3 2 Main Function 5 4 How To Control The Unit 10 4 1 Master Slave Built In Preprogrammed Function 11 4 2 DMX Controller 11 4 3 DMX 512 Configuration 12 4 4 DMX...

Page 3: ...close to the unit while operating as it is fire hazard Use safety cable when fixes this unit DO NOT handle the unit by taking its head only but always by taking its base Maximum ambient temperature is...

Page 4: ...bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating And make sure that the structure to which you are attaching the unit is secure and is able to suppor...

Page 5: ...e 45 Weight 6 3Kgs Dimension 1005 X 110 X 159mm 110 159 1005 3 How To Set The Unit 3 1 Control Panel 1 2 34 5 6 7 8 1 POWER IN Connect the main power supply 2 DMX IN For DMX512 link use 3 pin XLR cabl...

Page 6: ...UT For DMX512 link use 3 pin XLR cable to link the next unit and output DMX signal 3 2 Main Function To select any of the given functions press the MENU button up to when the required one is showing o...

Page 7: ...nnel Mode Show Mode Slave Mode Master Slave Blackout Mode Last state Sound State Sound Sense Led Display Inversion Auto Test Fixture Hours Software Version Reset Fixture Temperature olor Mode Dimmer S...

Page 8: ...press the MENU button again Hold and press the MENU button about one second or wait for one minute to exit the menu mode Show Mode Press the MENU button up to when the is shown on the display Pressing...

Page 9: ...old and press the MENU button about one second or wait for one minute to exit the menu mode Sound State Press the MENU button up to when the is shown on the display Pressing ENTER button Use DOWN and...

Page 10: ...again Hold and press the MENU button about one second or wait for one minute to exit the menu mode Display Inversion Press MENU button until is blinking on the display Use the DOWN and UP button to s...

Page 11: ...ENU button up to when the is blinking on the display Press the ENTER button and the display will show the temperature of the unit To go back to the functions press the MENU button Software version Pre...

Page 12: ...de and select Slave 1 normal or Slave 2 2 light show mode Their DMX cables plugged into the DMX input jacks daisy chain and the slave led lights will constantly on 2 light show In slave mode Slave 1 m...

Page 13: ...17 25 16 channels 1 17 33 49 32 channels 1 33 65 97 67 channels 1 68 135 202 4 3 DMX 512 Configuration 1 CH MODE MODE 1 CHANNEL VALUE FUNCTION 1 000 007 008 027 028 047 048 067 068 087 088 107 108 127...

Page 14: ...REEN 0 100 3 000 255 BLUE 0 100 4 0 255 WHITE 0 100 7 CH MODE MODE 4 CHANNEL VALUE FUNCTION 1 000 255 RED 0 100 2 000 255 GREEN 0 100 3 000 255 BLUE 0 100 4 000 255 WHITE 0 100 5 000 007 008 015 016 1...

Page 15: ...160 167 168 175 176 183 184 191 192 199 200 207 208 215 216 223 224 231 232 239 240 247 248 255 COLOR Off Color 1 Color 2 Color 3 Color 4 Color 5 Color 6 Color 7 Color 8 Color 9 Color 10 Color 11 Colo...

Page 16: ...16 CH MODE MODE 5 CHANNEL VALUE FUNCTION 1 000 255 RED 1 0 100 2 000 255 GREEN 1 0 100 3 000 255 BLUE 1 0 100 4 000 255 WHITE 1 0 100 5 000 255 RED 2 0 100 6 000 255 GREEN 2 0 100 7 000 255 BLUE 2 0...

Page 17: ...55 WHITE 3 0 100 13 000 255 RED 4 0 100 14 000 255 GREEN 4 0 100 15 000 255 BLUE 4 0 100 16 000 255 WHITE 4 0 100 17 000 255 RED 5 0 100 18 000 255 GREEN 5 0 100 19 000 255 BLUE 5 0 100 20 000 255 WHI...

Page 18: ...255 BLUE 3 0 100 12 000 255 WHITE 3 0 100 13 000 255 RED 4 0 100 14 000 255 GREEN 4 0 100 15 000 255 BLUE 4 0 100 16 000 255 WHITE 4 0 100 61 000 255 RED 16 0 100 62 000 255 GREEN 16 0 100 63 000 255...

Page 19: ...68 175 176 183 184 191 192 199 200 207 208 215 216 223 224 231 232 239 240 247 248 255 Color 1 Color 2 Color 3 Color 4 Color 5 Color 6 Color 7 Color 8 Color 9 Color 10 Color 11 Color 12 Color 13 Color...

Page 20: ...a Y cable DMX 512 is a very high speed signal Inadequate or damaged cables soldered joints or corroded connectors can easily distort the signal and shut down the system 3 The DMX output and input con...

Page 21: ...f the DMX LED is on and no response to the channel check the address settings and DMX polarity 3 If you have intermittent DMX signal problems check the pins on connectors or on PCB of the unit or the...

Page 22: ...t be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surrounding can cause greater accumu...

Page 23: ...cordance with the provision of the Electromagnetic Compatibility EMC Directive 89 336 EEC EN55103 1 2009 A1 2012 EN55103 2 2009 EN61000 3 2 2014 EN61000 3 3 2013 Harmonized Standard EN 60598 1 2015 EN...

Page 24: ...Innovation Quality Performance 23A...

Reviews: