background image

CENTAURI-200 User Guide

VT-ENG-TMP-UG | Rev 1.1 | 31-Jul-19

Volansys-Confidential

Page 4 of 31

Revision History

Date

Version

Details of change

Author

Reviewers

Approvers

10-08-2019

Draft 0.1

Initial Draft

MK

KB, RT

KB

29-08-2019

1.0

First Release

MK

RT, NP

KB

12-12-2019

1.1

Added Zigbee device control in

section 5.

Updated IoTiFy link in Section 3

NP

KB

KB

06-02-2020

1.2

Updated section 4.3 and updated

the document for Zigbee support.

NP

KB

KB

04-03-2020

1.3

Corrected LED2 indication in

chapter 4.

NP

KB

KB

13-03-2020

1.4

Updeted device provisioning section NP

KB

KB

06-08-2020

1.5

Updated Switch indication in

Chapter 4

NP

KB

KB

19-10-2021

1.6

Added screenshots for complete

gateway registration process in

Section 4.4.1 and updated latest Z-

wave mikrobus module design

picture in Section 5.1.

NP

KB

KB

20-10-2021

2.0

Baselined the document

NP

KB

KB

02-06-2022

3.0

Updated the logo in the document

YP

NP

NP

Summary of Contents for VOLANSYS CENTAURI-200

Page 1: ...lity Notice Copyright 2020Volansys All rights reserved This document is authored by Volansys and is Volansys intellectual property including the copyrights in all countries in the world This document is provided under a license to use only with all other rights including ownership rights being retained by Volansys This file may not be distributed copied or reproduced in any manner electronic or ot...

Page 2: ...WAY SETUP 13 4 1 GATEWAY LED INDICATION 13 4 2 GATEWAY SWITCH FUNCTION 13 4 3 GATEWAY INITIAL SETUP 14 4 3 1 Gateway Setup with Wi Fi 14 4 3 2 Gateway Setup with Ethernet cable 14 4 4 GATEWAY COMMISSIONING REGISTRATION 15 4 4 1 Gateway Registration 15 4 4 2 Factory reset the gateway 19 4 5 CHANGE GATEWAY NETWORK INTERFACE FOR IP CONNECTIVITY WI FI OR ETHERNET 21 4 5 1 Change from Wi Fi to Ethernet...

Page 3: ...Y PROPERTY CHANGE 19 FIGURE 4 6 GATEWAY WI FI RESET BUTTON 20 FIGURE 4 7 REMOVE GATEWAY 22 FIGURE 5 1 MIKROBUS BASED Z WAVE 700 MODULE 23 FIGURE 5 2 MIKROBUS BASED ZIGBEE JN5179 MODULE 23 FIGURE 5 3 END DEVICE LISTING SCREEN WITH NO END DEVICE PAIRED 25 FIGURE 5 4 COMMISSIONED GATEWAY 25 FIGURE 5 5 WAITING FOR END DEVICE PAIRING 25 FIGURE 5 6 SUCCESSFUL END DEVICE LISTING 26 FIGURE 5 7 END DEVICE ...

Page 4: ...B 06 02 2020 1 2 Updated section 4 3 and updated the document for Zigbee support NP KB KB 04 03 2020 1 3 Corrected LED2 indication in chapter 4 NP KB KB 13 03 2020 1 4 Updeted device provisioning section NP KB KB 06 08 2020 1 5 Updated Switch indication in Chapter 4 NP KB KB 19 10 2021 1 6 Added screenshots for complete gateway registration process in Section 4 4 1 and updated latest Z wave mikrob...

Page 5: ... that CENTAURI 200 is available with the user and flashed with the latest CENTAURI 200 release links for software release mobile application and necessary accounts to set up the Cloud application 1 2 2 Supported Software and Hardware Platforms CENTAURI 200 functionality is tested with the following combination of operating system hardware platform software versions phone model or iOS Android versi...

Page 6: ...ed Unique Identifier OTA Over The Air 1 4 References Reference Document Title Provided by Remarks NA 1 5 Document Conventions This element signifies a useful information or tip or suggestion This element signifies a warning or proceed with caution This element signifies that the action should be avoid ...

Page 7: ...onitor the Z wave and ZigBee end devices with help of mobile application To do the setup the user needs to provide Internet connectivity to CENTAURI 200 Gateway The Gateway supports Ethernet WiFi and LTE to connect to the cloud The user can add end devices in the system using mobile application Once the end devices are added to the system the user can control them via the mobile application Figure...

Page 8: ...ms to fulfill setup requirement CENTAURI 200 Gateway o Z wave controller Module o ZigBee Controller Module o Internet connectivity on Gateway via Ethernet or Wi Fi 2 2 Hardware Optional Requirements The following Z Wave ZigBee end devices are supported o Z Wave bulb door sensor motion sensor Multi sensor etc o ZigBee bulb door sensor motion sensor Water Leak Sensor etc ...

Page 9: ...dential Page 9 of 31 3 MOBILE APPLICATION SETUP 3 1 Installation Android Mobile Application 1 The IoTify Android application is available on Google Play Store 3 2 Installation iOS Mobile Application 1 The IoTify iOS application is available on the Apple Application store ...

Page 10: ...d User registration 1 Launch open installed application in the mobile User can see below screen Figure 3 1 Mobile Application Launch Page 2 If prompted for any permission please allow 3 Follow user registration process for creating account Enter verification code received on email to complete registration process ...

Page 11: ...ge 11 of 31 Figure 3 2 User registration for Gateway 4 Login with the user credential created during sign up 5 On successful authentication user is redirected to the list of registered gateways The user can see registered gateway if any or can see below screen without any gateways ...

Page 12: ...CENTAURI 200 User Guide VT ENG TMP UG Rev 1 1 31 Jul 19 Volansys Confidential Page 12 of 31 Figure 3 3 Home screen after successful login ...

Page 13: ...D2 Green Internet connectivity available Red Internet connectivity NOT available Switch Control Action SW1 Press the switch thrice where the interval between two consecutive presses should not exceed 1 second OTA Recovery in case of failure in the application OTA Press the switch for more than 10 seconds RF Device Discovery will start to pair end devices SW2 Press the switch thrice where the inter...

Page 14: ...ddress 5 Observe the LED indication o LED2 as solid RED indicates no internet connectivity if gateway doesn t have valid Wi Fi credential or does not have LAN or LTE connectivity Wi Fi credential can be provided to gateway through mobile application o LED1 as solid RED indicates Gateway is in Wi Fi access point mode o Refer section Gateway LED indication for more details 4 3 2 Gateway Setup with E...

Page 15: ... of the gateway is registered previously with same user id 2 User can add Gateway by touching on top right corner It will show below screen Follow the instruction given on screen On Wi Fi setting user shall connect to SSID CentauriGateway_XXXX XXXX Last 4 digit of Gateway MAC User should enter the Password as centauri_XXXX XXXX Last 4 digit of Gateway MAC e g centauri_D1A5 password is case sensiti...

Page 16: ...4 2 IoTify Add Gateway Once user connects to access point of the GW the user needs to enter the Wi Fi password as centauri_XXXX XXXX Last 4 digit of Gateway MAC e g centauri_D1A5 After the user comes back to this application user will see below screen In this screen user shall select an Access point ...

Page 17: ...31 Jul 19 Volansys Confidential Page 17 of 31 that GW will use for getting an internet connectivity E g Home Wi Fi router access point User will be prompted to enter passphrase if that is configured on selected SSID Figure 4 3 Gateway Provisioning ...

Page 18: ...ut the gateway will be commissioned and it will be available on application as shown below User can add multiple gateway to the application by following same process Figure 4 4 Gateway List 2 Long press on Gateway and select Gateway information This will open Gateway property window User can rename the gateway in this screen ...

Page 19: ...v 1 1 31 Jul 19 Volansys Confidential Page 19 of 31 Figure 4 5 Gateway property change 4 4 2 Factory reset the gateway 1 SW2 switch can be used long press to factory reset the gateway if needed Refer Gateway Switch indication for more details ...

Page 20: ...G TMP UG Rev 1 1 31 Jul 19 Volansys Confidential Page 20 of 31 Figure 4 6 Gateway Wi Fi reset button o User can see LED2 will turn green if Gateway has internet connectivity o LED2 will be red if there is not internet connectivity ...

Page 21: ...ud Refer section Gateway LED indication for more details 4 Once the LED2 turns Green connect to GW access point as mentioned earlier and select Ethernet during commissioning process 5 The LED2 must become Solid Green for controlling and managing gateway and end devices 4 5 2 Change from Ethernet to Wi Fi Follow below steps to change Network interface from Ethernet to Wi Fi 1 Power ON Gateway and w...

Page 22: ...eway To remove Gateway from registered gateway list follow below steps 1 The gateway must be powered on and connected to the cloud Confirm LED2 must be solid green GW should be shown Green on mobile application as well 2 Open Mobile application and select the Gateway to be removed Figure 4 7 Remove Gateway ...

Page 23: ...list 2 Click on the registered gateway in which the user wants to add the Z Wave ZigBee end device 3 The user can see the registered end device list If any end device is already registered they will be shown if not the below screen will be displayed 4 To commission the end device select the End node commissioning option from menu top right side of the screen 5 Gateway will open end device provisio...

Page 24: ...G Rev 1 1 31 Jul 19 Volansys Confidential Page 24 of 31 Note While commissioning end device at a time only one Z Wave device can be paired Once the first Z wave device is paired successfully another device can be paired with CENTAURI 200 ...

Page 25: ...User Guide VT ENG TMP UG Rev 1 1 31 Jul 19 Volansys Confidential Page 25 of 31 Figure 5 3 End device listing screen with no end device paired Figure 5 4 Commissioned Gateway Figure 5 5 Waiting for end device pairing ...

Page 26: ...31 Jul 19 Volansys Confidential Page 26 of 31 Figure 5 6 Successful end device listing 5 3 End Device Properties 1 You can rename the end device from device property screen by Device information from listed devices Figure 5 7 End device information ...

Page 27: ...dential Page 27 of 31 5 4 Z Wave ZigBee end Device controlling and monitoring 5 4 1 Z Wave ZigBee bulb control 1 Select gateway in mobile application and select desired bulb to control the brightness See below Figure 5 8 Zigbee Z wave bulb control from mobile application ...

Page 28: ... Rev 1 1 31 Jul 19 Volansys Confidential Page 28 of 31 5 4 2 Z Wave ZigBee device monitoring 1 Select gateway in mobile and select desired monitoring device See below Figure 5 9 ZigBee Z wave door sensor monitoring from mobile application ...

Page 29: ...Z Wave End Device 1 Select desired Gateway and choose Remove Z Wave device from menu 2 Gateway will open end device remove window Now follow instruction given in user manual of specific end device to unpair it from Gateway E g For bulb switch on off to unpair This will be manufacturer specific 3 If device is removed successfully user will see it removed from application ...

Page 30: ...e End Device 1 Long press on any added device from Devices screen to be removed 2 IoTify will open end device remove window Now follow instruction given in user manual of specific end device to unpair it from HomeBridge E g For bulb switch on off to unpaired This will be manufacturer specific 3 If device is removed successfully user will see it removed from application ...

Page 31: ...CENTAURI 200 User Guide VT ENG TMP UG Rev 1 1 31 Jul 19 Volansys Confidential Page 31 of 31 Figure 5 12 ZigBee remove end device from mobile application ...

Reviews: