![Acksys MI400 Series Technical Documentation Manual Download Page 58](http://html1.mh-extra.com/html/acksys/mi400-series/mi400-series_technical-documentation-manual_458117058.webp)
: COMPONENT TEST
drying
H
U
M
I
D
I
T
Y
TEMPERATURE TEST OF BOARD AND ELECTRONIC SUB-ASSEMBLIES
free H
422’
free H
30’
+80
+20
20’
24’
TIME
100
200
300
400
500
28’
600
700
800
+20
900
STOP
60’
1000
436’
T
E
M
P
E
R
A
T
U
R
E
-20
ON
OFF
OFF
P
O
W
E
R
DURATION OF FIRST PHASE = 480 minutes
COLD , POWER ON PERMANENTLY
DURATION OF SECOND PHASE = 480 minutes
HOT , POWER ON PERMANENTLY
END
FINAL
TEMPERATURE = 20 C
PAGE 6-2