CONNECTORS AND SWITHES
RKMI400/RTS
POWER
TX
ACKSYS
FRONT
REAR
CAT
1 2 3 4 5 6 7 8 910
on
SW4
SW5
ST2
PROTECTION TO GROUND
ONLY IF LIGHTNING OPTION:
STRAP CONNECTING THE LIGHTNING
WARNING !!! :
DECONNECTING THIS STRAP REMOVES
LIGHTNING PROTECTION
P2
SUB D 9 MALE
SW1
SW2
1
2
3
4
5
6
7
8
o
n
9
10
SW5
SW4
1
2
3
4
5
o
n
RX
RTS/DTR
CTS
DTE
DCE
2
3
2
DSR/DCD
6
7
8
1
2
3
4
5
6
7
8
o
n
9
10
4
2
2
-
4
8
5
SW3
MSTB2.5/5GF5.08
PHOENIX CONTACT 5 POINT MALE
P3
P4
POWER CONNECTOR
RKMI...
SW1
232
DTE
DCE
SW1 = DTE/DCE
INTERFACE SELECTION
SW2
1 2 3 4 5 6 7 8
on
232
1 = TRANSMISSION VALIDATION
2 = TRANSMISSION VALIDATION
3 = TRANSMISSION VALIDATION
4 = CTS CONTROL
5 = CTS CONTROL
SW3
1 2 3 4 5 6 7
on
422-485
1 = RS422A MODE
5 = RS485 MODE
2 = RS422A TERMINATION RESISTOR
3 = RS422A -BIAS
4 = BIAS
8 910
1 2 3 4 5 6 7 8 910
on
SW4
1 =
2 =
3 =
4 =
5 =
A
T
RANSMISSION
SPEED SELECTION
SPEED SELECTION
SPEED SELECTION
SPEED SELECTION
SPEED SELECTION
UTOMATIC
SW5
C
ONTROL
SW5 = SELECTION OF TRANSMISSION
VALIDATION BY RTS/DTR
OR AUTOMATICALLY
(CAT)
6 =
7 =
8 =
9 =
10 =
FORMAT SELECTION
FORMAT SELECTION
FORMAT SELECTION
FORMAT SELECTION
FORMAT SELECTION
L.E.D. ON FRONT
RS422-485
9 = RS485 ECHO
10 = UNSUSED
6 = RS485 TERMINATION RESISTOR
7 = RS485 -BIAS
8 = RS485 +BIAS
6 = CTS DELAY
7 = DSR/DCD CONTROL
8 = DSR/DCD CONTROL
4
5
37
1
2
3
FEMALE LINE CONNECTOR
SCREW CONNECTOR +
CABLE COVER WITH PHEONIX
STRAPS MSTB2.5/5STF5.08
CONTACT 5 POINT FEMALE
18 GAUGE MAXIMUM 2.5 mm2
(P3)
1 2
P3
= +RX
= -RX
= +TX
= GND
RS422A mode
= -TX
1
2
3
4
5
3 4 5
RS485 mode
= NC
= NC
= +TX/+RX
= -TX/-RX
= GND
1
2
3
4
5
signal " ON "
SEE CONFIGURATION TABLE
PAGE 3-5 AND PAGE 3-6
signal " OFF "
PAGE 3-3
Summary of Contents for MI400 Series
Page 2: ......
Page 6: ...NOTES ...
Page 16: ...NOTES ...
Page 17: ...SECTION 2 MI400 Series MI400 RKMI400 MI400 24V ...
Page 18: ...NOTES ...
Page 29: ...SECTION 3 MI400 RTS Series MI400 RTS MI400 24V RTS RKMI400 RTS ...
Page 30: ...NOTES ...
Page 40: ...NOTES ...
Page 41: ...SECTION 4 MI400 400 Series MI400 400 ...
Page 42: ...NOTES ...
Page 47: ...SECTION 5 Assembly Examples With FIXING PLATE RDMI RKMI ...
Page 48: ...NOTES ...
Page 54: ...NOTES ...
Page 55: ...SECTION 6 Temperature Tests ...
Page 56: ...NOTES ...
Page 60: ...NOTES ...
Page 61: ...APPENDIX A Distribution Signals ...
Page 62: ...NOTES ...
Page 65: ...APPENDIX B Troubleshooting ...
Page 66: ...NOTES ...
Page 69: ...APPENDIX C Extract from EIA standard Cable length ...
Page 70: ...NOTES ...
Page 78: ......