PRODUCT SPECIFICATIONS

Automation Components, Inc.

2305 Pleasant View Road  |  Middleton, WI 53562

Phone:

 1-888-967-5224  |  

Website:

 workaci.com

Page 7

Version: 7.0

I0000598

WARRANTY

The AUD Series is covered by ACI’s Two (2) Year Limited Warranty, which is located in the front of ACI’S SENSORS & 
TRANSMITTERS CATALOG or can be found on ACI’s website: www.workaci.com.

24 VDC (24 VDC to 35 VDC) or 24 VAC (21.6 VAC to 28 VAC), 50/60 Hz.

208 mA maximum 

Relay contact closure, transistor, or triac (24 VAC, 50/60 Hz)

Normal Mode: 

5 to 26.4 VDC, 24 to 26.4 VAC  |  

Triac Mode:

 24 to 26.4 VAC

See page #3

0 to 1 VDC, 0 to 4 VDC, 0 to 10 VDC, 0 to 13 VDC, 1 to 2 VDC, 1 to 5 VDC, 1 to 11 VDC,  

1 to 14 VDC

0 to 20 VDC (with adjustable offset and span)

3300Ω minimum at 20 VDC ± 10% , 400 ohms minimum at 10 VDC ± 10% (If the 

voltage output is limited to 18 VDC on the high end of the output span, the DC supply 

limit can be 24 VDC –10% and maintain stated accuracy

0 to 16 mA, 4 to 20 mA

0 to 20 mA (with adjustable offset and span)

0 to 750Ω maximum (If the load is lowered to 700Ω, the DC supply can be 24 VDC –10% 

and maintain stated accuracy

Ab/- 2% of span for adjustable ranges, 5% for preset

Ab/- 3% of span for adjustable ranges, 5% for preset

256 steps (all ranges)

24 VDC (+/- 10%), 48 mA maximum

90° Pluggable Screw Terminal Blocks

16 (1.31 mm2) to 26 AWG (0.129 mm2)

0.5 Nm (Minimum); 0.6 Nm (Maximum)

35 to 120°F (1.7 to 48.9°C)

10 to 95% non-condensing 

-20 to 150°F (-28.9 to 65.5°C)

NON-SPECIFIC INFORMATION

 

Supply Voltage:
Supply Current: 
Input Signal Source:
Input Signal Trigger Level:
Input Full Range Rates of Change:
Output Voltage Fixed Signal 
Ranges:
Output Voltage Adjustable Signal 
Ranges:
Output Voltage Signal Load:

Output Current Fixed Signal Ranges:
Output Current Adjustable Signal 
Ranges:
Output Current Signal Load:

Output Signal Accuracy (24 VAC, 60 
Hz): 
Output Signal Accuracy (24 VAC, 50 
Hz):
Output Signal Resolution:
Regulated Power Output (User): 
Connections:
Wire Size:
Terminal Block Torque Rating:
Operating Temperature Range: 
Operating Humidity Range:
Storage Temperature:

Summary of Contents for INTERFACE AUD

Page 1: ...rd may be mounted in any position If circuit board slides out of snap track a non conductive stop may be required Use only fingers to remove board from snap track Slide out of snap track or push against side of snap track and lift that side of the circuit board to remove Do not flex board or use tools WIRING INSTRUCTIONS PRECAUTIONS Remove power before wiring Never connect or disconnect wiring wit...

Page 2: ...OWN Output Pulsed relay contacts not Isolated PWR UP DWN 24V SIG E2 Wiring diagram for TEC controller mfg by Siemens Building Technologies Inc Landis Division PWR UP DWN 24V SIG E4 Triac 24 VAC from Controller Can share same power supply as TEC Controller N O N O C C NRM TRC U D J1 Triac Jumper Positon E5 24 VAC DC Power Supply Note If the end device has an earth ground SCR VFD the ground common m...

Page 3: ...ds to version ordered See Table 1 2 Select either current or voltage output with the two switches shown in Figure B on p 4 NEVER have both switches on or off at the same time while powered or chip failure may occur 3 Select offset of 1 volt 4 mA or adjustable offset by switch 6 as shown in Figure C With the adjustable offset setting you can adjust the OFFSET trim pot as desired For offset higher t...

Page 4: ... Turn power OFF set DIP switch 6 for adjustable offset see Figure 3 connect multimeter to the output and turn the power on Place Man Auto jumper in the Manual position Turn the Manual Override potentiometer counter clockwise until it stops It is a 3 4 turn pot Offset Pot turns counter clockwise to Decrease and clockwise to Increase Turn the Offset potentiometer until the desired minimum output is ...

Page 5: ...he hookup to the actuator place Jumper J2 in MAN manual position and turn the manual potentiometer Be sure to return Jumper J2 to AUTO position after testing TROUBLE SHOOTING AND TESTING 1 Apply 24 VAC or 24 VDC to PWR terminal confirm power LED is on and measure voltage to confirm proper voltage 2 Check the DIP settings Depressing the switch closest to the MAN AUTO pot selects the ON position You...

Page 6: ...stated above If no contact ACI Tech Support at 888 967 5224 If yes current output is functioning properly 4 Testing the input To manually test the input Apply 24 VAC or 24 VDC to the PWR terminal Connect your meter to the SIG and PWR terminal Set meter to match output DIP switch settings Place MAN AUTO jumper to AUTO Connect a jumper wire from UP to the PWR Connect a jumper wire to the PWR only Yo...

Page 7: ...uracy 0 to 16 mA 4 to 20 mA 0 to 20 mA with adjustable offset and span 0 to 750Ω maximum If the load is lowered to 700Ω the DC supply can be 24 VDC 10 and maintain stated accuracy Absolute 2 of span for adjustable ranges 5 for preset Absolute 3 of span for adjustable ranges 5 for preset 256 steps all ranges 24 VDC 10 48 mA maximum 90 Pluggable Screw Terminal Blocks 16 1 31 mm2 to 26 AWG 0 129 mm2 ...

Page 8: ...nc 2305 Pleasant View Road Middleton WI 53562 Phone 1 888 967 5224 Website workaci com Page 8 Automation Components Inc 2305 Pleasant View Road Middleton WI 53562 Phone 1 888 967 5224 Website workaci com Version 7 0 I0000598 ...

Reviews: