A
CHI
®
17
1/The meaning of“
Hb
”:
“
Hb
” means the max heating temperature of the upper heating. We set the max
temperature at 230°C according to the max temperatrue of lead-free Reweork and
other technical reasons.
The data needn’t to be changed.
2/The meaning of
“r1” “L1” “d1” “r2” “L2” “d2” “r3” “L3” “d3” ……
Please pay attention to The following pictures and tables:
S.N.
Mnemonic
Parameter
Adjustable Range
1
r1
Ramp Rate 1
1
2
L1
Target Setpoint 1
0
230
End
3
d1
Dwell Time 1
0
9999sec
4
r2
Ramp Rate 2
1
5
L2
Target Setpoint 2
0
230
End
6
d2
Dwell Time 2
0
9999sec
7
r3
Ramp Rate 2
1
8
L3
Target Setpoint 2
0
230
End
9
d3
Dwell Time 2
0
9999sec
…
…
…
…
Hb
230
Rework temperature curve to set examples
Lead Sn63Pb37
PTN- 1
r1
1
L1
85
d1
70
r2
1
L2
150
d2
35
r3
1
L3
185
d3
50
r4
END
Hb
230
Lead-Free
Sn96.5Ag3Cu0.5
PTN- 2
r1
1
L1
85
d1
60
r2
1
L2
140
d2
45
r3
1
L3
170
d3
25
r4
1
L4
220
d4
50
r5
END
Hb
230