- 34 -
5. Level 1 Cosmetic / Appearance / Alignment Service
5.1 Alignment procedure (for function adjustment)
5.1.1 Preparation
1. Setup input timing to any preset modes or patterns.
2. Enter factory mode (press “Empowering” & “Power” buttons at the same time to turn on monitor).
3. Move cursor into “Burn-in Mode” tag and select “On” to enable burn-in mode.
4. Power off the monitor, remove the input source and then power on again.
5. Setup unit and keep it warm up for at least 30 minutes.
6. Setup input timing ICL-605( 1280x1024@75Hz ), 32-Grays pattern.
7. Setup unit and keep it warm up at least 30 minutes.
5.1.2. Timing adjustment:
1. Enter factory setting area (press “
Empowering
” and then press “SOFTPOWER”).
2. Check the settings to following values:
Contrast = 50
Brightness = 85
Color = Warm
Language = English
Then, turn off the monitor power.
3. Turn on power enter user area.