P3150/P3250/P3150 Refresh/P3250 Refresh
Confidential
3-5
No
Symptom
Procedure
3
No Image
• Ensure the Signal Cable and Source work
(If you connect multiple sources at the same time, use the
“Source” button on the control panel to switch)
• Ensure all connectors are securely connected and aren’t bro
-
ken
• Check Main Board
• Check DMD Board
• Check Colour Wheel
• Check DMD Chip
• Check Engine Module
4
No Light On
• Ensure all connectors are securely connected and aren’t
broken
• Check Lamp Module
• Check Lamp Driver
• Check LVPS
• Check Main Board
5
Mechanical Noise
• Check Colour Wheel
• Check Fan Module
6
Line Bar/Line Defect
• Check if the Main Board and the DMD Board are assembled
properly
• Check Main Board
• Check DMD Board
• Check DMD Chip
Summary of Contents for P3250 Refresh