4
The unit should suffer no visible cosmetic damage and should operate with no degradation in display
quality during exposure to the operating conditions and after exposure to the non-operating conditions,
in any sequence.
2.1 Environmental conditions
Operating
Specification
Temperature range
0°C to 40°C
Relative humidity
20% to 80%
Altitude
0 to 3048M (10000 ft)
Storage
Temperature range
-
25°C to 60°C
Relative humidity
5% to 80%
Altitude
0 to 9144M (30000 ft)
2.2 Safety, EMC, Ergonomics and Compatibility Requirements
Items Description
UL/cUL CB TUV/GS CCC
Other
Safety
●
●
●
●
FCC CE CCC VCCI-B
EMC
●
●
●
●
TCO99 TCO03
Ergonomics
●
●
Windows 95/98/Me
Windows 2000
Windows XP
vista
Compatibility
●
●
●
●
Energy Star
Power
Management
●
2.3 Electrostatic Discharge Requirements
Item
Condition
Spec
Contact discharge : +4KV
Contact discharge : +8KV
●
Air discharge : + 8KV
Electrostatic Discharge
IEC61000-4-2(EN55024)
Air discharge : +15KV
●
2.4 Reliability
Items
Condition
Spec
Note
MTBF
≧
40,000
Hours
Excluding the
LCD, CCFL
CCFL Life time
Luminance becomes 50%
≧
40,000 Hours(min)
Note1
Note1
.
Display an all WHITE field at mid Brightness and Contrast settings.
2. Electrical and Optical Characteristics and Performance
3.1 Main Power Supply
Items
Condition
Spec
Note
AC Input Voltage Range
Universal input full range
100~240VAC /50~60Hz
Summary of Contents for B193
Page 1: ... 0 Service Manual LCD Monitor Acer B V193 ...
Page 16: ...15 Note Please see the configure as below Figure 6 Programmi ng speed Configure Inform ...
Page 18: ...17 02 Flat Panel Specification ...
Page 43: ......
Page 44: ......
Page 45: ...22 04 Troubleshooting ...
Page 46: ...23 ...
Page 47: ...24 ...
Page 50: ...27 06 Schematics and Layouts 6 1 Inverter PWM circuit ...