H a n n St a r D i s p l a y C o r p .
Document Title
HSD190MEN3-A
Specification for Innolux
Page No.
5 / 26
Document No.
DC130-002772
Revision
1.0
The information contained in this document is the exclusive property of HannStar Display Corporation. It shall not
be disclosed, distributed or reproduced in whole or in part without written permission of HannStar Display
Corporation.
1.5 Mechanical
Information
Item Min.
Typ.
Max.
Unit
Horizontal(H) 395.5
396.0
396.5 mm
Vertical(V) 323.5 324.0 324.5 mm
Module Size
Depth(D) 16.5
mm
Weight (without inverter)
--
1950
--
g
Torque of customer screw hole
--
--
3.0 Kgf*Cm
2.0 ABSOLUTE MAXIMUM RATINGS
2.1 Absolute Rating of Environment
Item Symbol
Min.
Max.
Unit
Note
Storage temperature
T
STG
-20 60
o
C
Operating temperature
T
OPR
0 50
o
C (1)
Vibration (non-operating)
V
NOP
-- 1.5 G (2)
Shock (non-operating)
S
NOP
-- 70 G (3)
Storage humidity
H
STG
10 90 %RH (3)
Operating humidity
H
OP
10 80 %RH (4)
Low pressure (operating)
P
LOP
697 -- HPa (5)
Low pressure (non-operating)
P
LNOP
116 -- HPa (6)
Note (1)Storage /Operating temperature
100
80
40
20
0
0
20
40
60
-20
-40
10
50
90
Humidity (%)
Temperature (
o
C)
Operating Range
Storage Range
65
60
Summary of Contents for B193
Page 1: ... 0 Service Manual LCD Monitor Acer B V193 ...
Page 16: ...15 Note Please see the configure as below Figure 6 Programmi ng speed Configure Inform ...
Page 18: ...17 02 Flat Panel Specification ...
Page 43: ......
Page 44: ......
Page 45: ...22 04 Troubleshooting ...
Page 46: ...23 ...
Page 47: ...24 ...
Page 50: ...27 06 Schematics and Layouts 6 1 Inverter PWM circuit ...