Reliability Performance
Electrostatic Discharge Requirements
This display shall withstand 4kV for contact discharge and 8kV for air discharge of Electrostatic
Discharge to meet the acceptance criteria as specified in EN55024.
Hinge Life
Mean time between failure (MTBF)
For the purposes of demonstrating the MTBF of this product, a failure is defined as the inability of the
product to function in accordance with this specification. A failure event interrupts the expected operation
of the product and requires service or repair to restore the product to full functionality.
The MTBF of this product shall be demonstrated to meet or exceed 50,000 hours @ 25 °C at a 90%
lower confidence limit under all operating conditions as specified in previous section. ( Lamp life is not
included )
All components including power and inverter shall be derate to 80% for active devices, 80% for
capacitors and 50% for resistive components, except for polarized capacitors which may be operated at 90%
of voltage - which are all calculated under worst case conditions.
Mean Time Between Replace ( MTTR )
This display shall be well designed to take less than 5 minutes for replacing control board or inverter
board.
Note: If there is anything not clarified or specified on this specification, PVT sample shall
be a standard reference.
Summary of Contents for AT2001
Page 11: ...Pin Definition Between Main Board and I O Board ...
Page 26: ...Remote Controller Key Definition ...
Page 30: ...OSD Menu Abstract Structure OSD Menu for EURO ...
Page 31: ...OSD Translations ...
Page 53: ...47 Chapter 4 ...
Page 55: ...48 Chapter 6 Exploded Diagram ...