Chapter 4
67
Memory check
Memory errors might stop system operations, show error messages on the screen, or hang the system.
1.
Boot from the diagnostics diskette and start the doagmpstotics program (please refer to main board.
2.
Go to the diagnostic memory in the test items.
3.
Press F2 in the test items.
4.
Follow the instructions in the message window.
NOTE:
Make sure that the DIMM is fully installed into the connector. A loose connection can cause an error.
Power System Check
To verify the symptom of the problem, power on the computer using each of the following power sources:
1.
Remove the battery pack.
2.
Connect the power adapter and check that power is supplied.
3.
Disconnect the power adapter and install the charged battery pack; then check that power is supplied by
the battery pack.
If you suspect a power problem, see the appropriate power supply check in the following list:
“Check the Power Adapter” on page 67
“Check the Battery Pack” on page 67
Check the Power Adapter
Unplug the power adapter cable from the computer and measure the output voltage at the plug of the power
adapter cable. See the following figure
1.
If the voltage is not correct, replace the power adapter.
2.
If the voltage is within the range, do the following:
z
Replace the System board.
z
If the problem is not corrected, see “Undetermined Problems” on page 82.
z
If the voltage is not correct, go to the next step.
NOTE:
An audible noise from the power adapter does not always indicate a defect.
3.
If the power-on indicator does not light up, check the power cord of the power adapter for correct
continuity and installation.
4.
If the operational charge does not work, see “Check the Battery Pack” on page 67.
Check the Battery Pack
To check the battery pack, do the following:
From Software:
1.
Check out the Power Management in control Panel
2.
In Power Meter, confirm that if the parameters shown in the screen for Current Power Source and Total
Battery Power Remaining are correct.
3.
Repeat the steps 1 and 2, for both battery and adapter.
4.
This helps you identify first the problem is on recharging or discharging.
Pin 1: +19 to +20.5V
Pin 2: 0V, Ground
Summary of Contents for Aspire 8930 Series
Page 6: ...VI ...
Page 9: ...Chapter 1 3 System Block Diagram ...
Page 56: ...50 Chapter 3 LCM module disassembly flow chart ...
Page 63: ...Chapter 3 57 25 Then remove the switch cover from the machine ...
Page 67: ...Chapter 3 61 21 Remove the USB board from BTCB ...
Page 92: ...86 Chapter 6 Aspire 8930 Exploded Diagram ...
Page 93: ...Chapter 6 87 ...
Page 94: ...88 Chapter 6 ...
Page 95: ...Chapter 6 89 ...
Page 96: ...90 Chapter 6 ...
Page 97: ...Chapter 6 91 ...
Page 98: ...92 Chapter 6 ...
Page 99: ...Chapter 6 93 ...
Page 100: ...94 Chapter 6 ...
Page 101: ...Chapter 6 95 ...
Page 102: ...96 Chapter 6 ...
Page 103: ...Chapter 6 97 ...
Page 104: ...98 Chapter 6 ...
Page 105: ...Chapter 6 99 ...
Page 118: ...112 Chapter 6 ...