70
Chapter 4
System Check Procedures
External Diskette Drive Check
Do the following to isolate the problem to a controller, driver, or diskette. A write-enabled, diagnostic diskette is
required.
NOTE:
Make sure that the diskette does not have more than one label attached to it. Multiple labels can cause
damage to the drive or cause the drive to fail.
Do the following to select the test device.
1.
Boot from the diagnostics diskette and start the diagnostics program.
2.
See if FDD Test is passed as the program runs to FDD Test.
3.
Follow the instructions in the message window.
If an error occurs with the internal diskette drive, reconnect the diskette connector on the system board.
If the error still remains:
1.
Reconnect the external diskette drive/DVD-ROM module.
2.
Replace the external diskette drive/CD-ROM module.
3.
Replace the main board.
External CD-ROM Drive Check
Do the following to isolate the problem to a controller, drive, or CD-ROM. Make sure that the CD-ROM does
not have any label attached to it. The label can cause damage to the drive or can cause the drive to fail.
Do the following to select the test device:
1.
Boot from the diagnostics diskette and start the diagnostics program.
2.
See if CD-ROM Test is passed when the program runs to CD-ROM Test.
3.
Follow the instructions in the message window.
If an error occurs, reconnect the connector on the System board. If the error still remains:
1.
Reconnect the external diskette drive/CD-ROM module.
2.
Replace the external diskette drive/CD-ROM module.
3.
Replace the main board.
Keyboard or Auxiliary Input Device Check
Remove the external keyboard if the internal keyboard is to be tested.
If the internal keyboard does not work or an unexpected character appears, make sure that the flexible cable
extending from the keyboard is correctly seated in the connector on the system board.
If the keyboard cable connection is correct, run the Keyboard Test.
If the tests detect a keyboard problem, do the following one at a time to correct the problem. Do not replace a
non-defective FRU:
1.
Reconnect the keyboard cables.
2.
Replace the keyboard.
3.
Replace the main board.
The following auxiliary input devices are supported by this computer:
Numeric keypad
External keyboard
If any of these devices do not work, reconnect the cable connector and repeat the failing operation.
Summary of Contents for Aspire 6935 Series
Page 6: ...VI ...
Page 12: ...4 Chapter 1 System Block Diagram ...
Page 33: ...Chapter 1 25 ...
Page 35: ...Chapter 1 27 ...
Page 48: ...40 Chapter 1 ...
Page 66: ...56 Chapter 3 LCM module disassembly flow chart ...
Page 96: ...88 Chapter 5 Bottom View ...
Page 98: ...90 Chapter 5 ...
Page 100: ...92 Chapter 6 Aspire 6935G Exploded Diagram ...
Page 101: ...Chapter 6 93 ...
Page 102: ...94 Chapter 6 ...
Page 103: ...Chapter 6 95 ...
Page 104: ...96 Chapter 6 ...
Page 105: ...Chapter 6 97 ...
Page 106: ...98 Chapter 6 ...
Page 107: ...Chapter 6 99 ...
Page 108: ...100 Chapter 6 ...
Page 109: ...Chapter 6 101 ...
Page 110: ...102 Chapter 6 ...
Page 111: ...Chapter 6 103 ...
Page 112: ...104 Chapter 6 ...
Page 113: ...Chapter 6 105 ...
Page 114: ...106 Chapter 6 ...
Page 115: ...Chapter 6 107 ...