Chapter 4
77
WinPhlash Error Messages
Error Code
Error Message
-100
BCPSYS block signature was not found.
-101
BCPDMI block signature was not found.
-103
Platform Signature was not found in the interface.
-104
BIOS image checksum verification failed.
-105
Flash device size doesn’t match BIOS image size.
-106
New BIOS image size doesn’t match current system BIOS size.
-107
New DMI string size doesn’t match current system DMI string size.
-108
Flash device part number(s) doesn’t match part number(s)
specified in the interface descriptor.
-109
The current system BIOS is the same version as (or newer than)
the version you are trying to flash, so the BIOS will not be changed.
-110
The new BIOS image is hte same as the current system BIOS, so
the BIOS will not be changed.
-111
Part ID of System BIOS and new Image File of the System Platform
may be different from the image file.
-120
New BIOS part number doesn’t match system BIOS part number.
-121
Driver initialization failed.
-122
Driver failed to provide access to the BIOS memory.
-130
Driver failed to allocate memory.
-131
Different format of block descriptor was found or block descriptor
was damaged
-132
Invalid block attributes.
-133
Improper save/restore order detected in the block descriptor table.
-134
Different format of block descriptor was found or block size is
invalid.
-135
Different format of block descriptor was found or block offset is
invalid.
-136
Invalid/Different format of block descriptor was found.
-140
Invalid block umber was specified
-141
Failed to locate resource in the executable or DLL.
-142
Required device or platform function is not present.
-143
Driver failed to allocate descriptor.
-144
BIOS is not flashable.
-145
Block programming function failed.
-146
Block erase function failed.
-147
VPP is not at expected level.
-148
Erase sequence failed.
-149
BIOS image verification failed.
-150
BIOS interface function failed.
-151
The current device is not supported in the interface.
-160
Device Descriptor signature not found in the interface.
-161
Part Table Signature not found in the interface.
-162
Invalid Part Count found in the interface.
-163
Invalid Part Descriptor size found in the interface.
-164
Invalid Text Descriptor size found in the interface.
-165
Duplicate device support found in the interface.
Summary of Contents for Aspire 1510 Series
Page 6: ...VI ...
Page 36: ...28 Chapter 1 ...
Page 96: ...88 Chapter 4 ...
Page 100: ...92 Chapter 6 Exploded Diagram The Base LCD 14 1 15 0 ...
Page 101: ...Chapter 6 93 Main Board Module ...
Page 111: ...Chapter 6 103 ...
Page 120: ...112 Appendix C ...
Page 121: ...www s manuals com ...