- 28 -
For Hannstar HSD 150SX84-A4
Condition
Min.
Typ.
Max.
Unit
Input Voltage
---
---
12
---
V
Input Current
---
---
1.0
---
A
ON
0
1.0
V
Backlight ON/OFF Control
OFF 2.0
3.0
---
V
Brightness Adjust
(Lamp Current Control)
Min. Luminance / Max.
Luminance
--- 55% --- ---
Output Voltage
Vin=12, Iout=6.5mA
---
650
---
Vrms
HSD150SX84-B 200
250
---
Brightness
HSD150SX84-D 175
200
---
Cd/m²
Output Current(Each connector)
Vbri=0.5~3.2V
3
6.5
7
mA
Frequency ---
45
60
80
KHz
Open Lamp Voltage
at 0 °C
1100
---
---
Vrms
Striking Time
---
---
1.0
---
S
Lamp Current Balance
---
---
±0.3
---
mA
Efficiency Vin=12V
---
80
---
%
Operating Life Time
--- 40000
---
---
Hr
*.The open lamp voltage is testes at output connector terminal
* Life time(Hr)
1. Specified values are for a single lamp. When the brightness becomes 50%
2. The life is determined as the time at which brightness of the lamp is 50% compared to that of initial value at the
typical lamp current on condition of continuous operating at 25±2°C.
SAFETY
Leakage Current: 0.25mA @ 100Vac
Insulation Resistance: more than 3M ohms while withstanding a voltage of 500Vac
Hi-Pot: 3Kvac with using 3mA cut off current
Summary of Contents for AL1515
Page 15: ... 15 BLOCK DIAGRAM System Block Diagram MCU ...
Page 17: ... 17 Software flow chart ...
Page 41: ...41 Chapter 4 Troubleshooting Main Procedure ...
Page 42: ...42 Power Circuit and Backlights Troubleshooting ...
Page 43: ...43 Performance Troubleshooting ...
Page 44: ...44 Function Troubleshooting ...
Page 47: ...47 Model AL1515 ...
Page 48: ...48 Model AL1515 m ...
Page 51: ...55 ...
Page 52: ...56 ...
Page 53: ...57 ...
Page 54: ...58 ...
Page 55: ...59 ...
Page 56: ...60 ...
Page 57: ...61 ...
Page 58: ...62 ...
Page 59: ...63 ...
Page 60: ...64 ...
Page 61: ...65 ...