Chapter 1 - Getting Started 1-17
Table 1-1
System Error Messages
Error Message
Corrective Action
Bad CMOS Battery
Replace battery. Contact your dealer.
CMOS Checksum
Error
Run Setup. See Chapter 3.
Floppy Drive
Controller Error
Check and connect the cable to the floppy
drive or controller.
Floppy Drive Error
Floppy may be bad. If not, check the
floppy drive and replace if necessary.
DRAM Configuration
Error
Check and modify DRAM configuration to
agree with Table 4-1.
Equipment
Configuration Error
Run Setup. See Chapter 3.
Hard Disk Controller
Error
Check and connect the cable to the hard
disk drive or controller.
Hard Disk 0 (1, 2, 3)
Auto Detection
Failed
Replace the hard disk drive controller.
Check the HDD cable connections and
CMOS setup configuration.
I/O Parity Error
Contact your dealer.
PS/2 Keyboard
Error or No
Keyboard
Connected
Check and connect the keyboard to the
system unit.
PS/2 Keyboard
Interface Error
Contact your dealer.
Memory Error
Check DIMMs on the system board.
Contact your dealer.
Memory Size
Mismatch
Run Setup. See Chapter 3.
All manuals and user guides at all-guides.com