INS401 User’s Manual
_____________________________________________________________________________________
Doc# 7430-3305-08
Page 31
Header Msg_Type
Length
Data
CRC
0x5555 0xcc0b
0
--
2 bytes
Receive:
Header Msg_Type Length
Data
CRC
0x5555 0xcc0b
PRODUCT_NAME_STRING,
unit_version,
PART_NUMBER_STRING,
serialNum
2 bytes
Table 15 Jump to IAP (JI)
Send:
Header Msg_Type
Length
Data
CRC
0x5555 0xaa01
0
--
2 bytes
Receive:
This command is used to jump to BootLoader. This command can be sent regardless of whether
it is currently in the APP or BootLoader.
Table 16 Jump to APP (JA)
Send:
Header Msg_Ty
pe
Leng
th
Data
CRC
0x5555 0xaa02
4
rtkCRC_L
1 byte
rtkCRC_H
1 byte
insCRC_
L
1 byte
insCRC
_H
1 byte
2 bytes
Receive:
Header
Msg_Type Len
gth
Data
CRC
0x5555
0xaa02
6
‘
C
’ ‘
0
’
‘
S
’
-succ
‘
F
’
-Fail
‘
C
’ ‘
1
’
‘
S
’
-succ
‘
F
’
-Fail
2 bytes