15
Some system status can be checked by the controller but cannot be adjustable. Below is the list.
Status No.
Description
Range
Remarks
IN
Inlet water temp.
-9 ~ 99°C
Real test value
OUT
Outlet water temp.
-9 ~ 99°C
Real test value
P1
Coil temp.
-9 ~ 99°C
Real test value
P2
Reserved
-9 ~ 99°C
Real test value
ROOM
Ambient temperature
-9 ~ 99°C
Real test value
Malfunctioning of the unit and error codes
When an error occurs or the protection mode is set automatically, the circuit board and the wired
controller will both display the error message.
Protection/Malfunction
Error code
Error Indicator LED
Inlet water temp. sensor failure
PP 01
☆●
(One flash one black)
Outlet water temp. sensor failure
PP 02
☆☆●
(2flash 1 black)
Evaporator coil temp. sensor failure
PP 03
☆☆☆●
(3 flash 1 black)
Ambient temp. sensor failure
PP 05
☆☆☆☆☆●
(5flash 1 black)
Too much Inlet/outlet water temp.
difference protection
PP 06
bright
Winter freezing protection
PP 07
dark
Too low outlet water temp. protection
PP 08
bright
High pressure protection
EE 01
☆☆☆☆☆☆●
(6 flash 1 black)
Low pressure protection
EE 02
☆☆☆☆☆☆☆●
(7flash 1 black)
Water flow protection
EE 03
☆☆☆☆☆☆☆☆●
(8 flash1 black)
Too much Inlet/outlet water temp.
difference failure
EE 05
☆☆☆☆☆☆☆☆☆☆●
(10 flash 1
black)
Defrost
Defrosting
indicate
☆☆☆☆☆☆☆☆
……(Long flash)
Communication failure
EE 08