12
Bu
tt
ons
1.
Unit ON/OFF bu
tt
on
Press this bu
tt
on when the unit is standby, the unit can be turned ‘ON’ and runs on the se
tti
ng
mode. The running mode, temperatures,
ti
mer situa
ti
on and clock
ti
me are displayed on the screen.
Press this bu
tt
on again when the unit is running, the unit then will be turned ‘OFF’.
2.
Mode bu
tt
on
Press this bu
tt
on to select the running mode at any situa
ti
on. Each
ti
me this bu
tt
on is pressed, the
mode will change. It is applicable to hea
ti
ng & cooling unit.
(Remark: For model SDAW3.5-220, SDAW4.6-220, SDAW6.7-220, only
heatin
g mode is available.)
3.
And
adjust bu
tt
ons
These are the mu
lti
-purpose bu
tt
ons. Combining the se
tti
ng bu
tt
on, they are used for the
parameter se
tti
ng, parameter checking, clock adjustment and adjustment of the
ti
mer.
4.
Se
tti
ng bu
tt
on
This is the mul
ti
-purpose bu
tt
on. Combining the adjust bu
tt
ons, it is used for the parameter se
tti
ng,
parameter checking, clock adjustment and adjustment of the
ti
mer.
LCD icons
1.
Cooling mode
The icon indicates that the current opera
ti
on mode is cooling.
(Remark: For model SDAW3.5-220, SDAW4.6-220, SDAW6.7-220, only
heatin
g mode is available.)
2.
Hea
ti
ng mode
The icon indicates that the current opera
ti
on mode is hea
ti
ng.
3.
Defros
ti
ng
The icon indicates that the defros
ti
ng fun
cti
on is enabled. This is an automa
tic
fun
cti
on, the system
will entry or exit the defros
ti
ng according to the inner control program. The defros
ti
ng parameters
can be changed at
fiel
dwork. And the unit does not support manual defros
ti
ng control.
4.
Le
ft
temperature display
The display shows the current water inlet temperature.
If you want to check or adjust the parameter this sec
ti
on will display the rela
ti
ng parameter number.
In case when any malfunc
ti
on occurs, this sec
ti
on will display the related error code.
5.
Right temperature display
The display shows that the current water outlet temperature.
If you want to check or adjust the parameter this sec
ti
on will display the related parameter value.
In case when any malfunc
ti
on occurs, this sec
ti