MP5017-2002
Accu-Steam Gas Griddle
25
MODE
LED Indicators
DISPLAY
NOTES
Set Preset
Temperature
All indicator LEDs
blinking. Then the
selected preset key
will blink for 3 -5
seconds.
Set Point Value
Use the same process to change the
temperature as detailed in Set Temperature
(On the fly), to adjust the Set Temperature.
Once the correct temperature is displayed,
and before the five second time out, press
and hold the
Preset Temp 1
key or the
Preset Temp 2
key to save the displayed
value to the desired preset key and to exit
this mode. Press the
On/Off
key to exit
without saving.
Default Values:
Preset 1 =
375°F
Preset 2 =
400°F
Display
Temperature
Mode
Current Temperature
function LED on
Actual temperature
Pressing the
Asterisk
key and the
Up
Arrow
Key will display the current actual
temperature when the unit is in Ready Mode.
User Lockout
Mode
All LEDS on solid
“
Loc
”or “
ULoc
”
To Set USER LOCKOUT mode, press and
hold the
On/Off
key and the
Asterisk
key for approximately four seconds while the
controller is ON. After four seconds, the
USER LOCKOUT parameter will toggle and
the display will show either “
Loc
” or “
ULoc
”.
When buttons are released, the controller
will store the new USER LOCKOUT param-
eter value into NVM.
Up Arrow
key (Increment) and the
Down Arrow
key (Decrement) will be
inoperable and the user can’t store new
values into the
Preset
1
or
2
keys.
When
Up Arrow
key or the
Down
Arrow
key (Set temperature on the fly mode)
are held for three seconds the display will
show “
Loc
” when in the “Loc” mode