Rated maximum output 

power of transmitter  

(W)

Separation distance according to frequency of transmitter (m)

150 kHz to 80 MHz 

d

 = 1.2 √P

80 MHz to 800 MHz 

d

 = 1.2 √P

800 MHz to 2.5 GHz 

d

 = 2.3 √P

0.01

0.12

0.12

0.23

0.1

0.38

0.38

0.73

1

1.2

1.2

2.3

10

3.8

3.8

7.3

100

12

12

23

For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) 

can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power 

rating of the transmitter in watts (W) according to the transmitter manufacturer.

NOTE 1:

 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.

NOTE 2:

 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and 

reflection from structures, objects and people.

1)

 The warranty period for the device is one year 

from date of purchase. In case of a warranty 

claim, the date of purchase has to be proven 

by means of the sales receipt or invoice.

2)

 Repairs under warranty do not extend the 

warranty period for the device or for the 

replacement parts.

3)

 The following is excluded under the warranty:

 

All damage due to improper treatment, 

  e.g. nonobservance of the user instruction.

  n 

All damage due to repairs or tampering by  

  the customer or unauthorized third parties.

  n 

Damage during transport from the    

  manufacturer to the consumer or during  

  transport to the retailer.

  n 

Accessories which are subject to normal 

  wear and tear. 

4)

 Liability for direct or indirect consequential 

losses caused by the unit is excluded even 

if the damage to the unit is accepted as a 

warranty claim.

Please contact Compass Health Brands in 

case of a claim under the warranty. If you 

have to send in the unit, enclose a copy of 

your receipt and clearly state the defect. 

The following warranty terms apply:

  LIMITED WARRANTY

ACRL3100_Manual_03.indd   38-39

10/31/18   4:41 PM

Summary of Contents for ACRL-3100

Page 1: ...Dual 3 in 1 Electrotherapy Pain Relief User Manual Model ACRL 3100 ACRL3100_Manual_03 indd 1 10 31 18 4 41 PM ...

Page 2: ...s declares that the device complies with following normative documents IEC60601 1 IEC60601 1 2 I EC60601 2 10 IEC62366 IEC60601 1 11 ISO10993 5 ISO10993 10 ISO10993 1 ISO14971 TABLE OF CONTENTS Introduction 4 How TENS works for pain relief 5 How EMS works for muscle stimulation 6 Important safety precautions and warnings 7 Package contents 14 Know your device 15 Charging 18 Easy steps to get start...

Page 3: ...Guide 1PC E AAA Batteries 2PC What is it The Dual 3 in 1 ACRL 3100 is a dual output channel TENS machine and highly effective in temporarily relieving minor pain TENS therapy is now regularly recommended by doctors physiotherapists and pharmacists throughout the world Transcutaneous Electrical Nerve Stimulation TENS is a noninvasive drug free method of controlling pain TENS uses tiny electrical im...

Page 4: ...cise passively It is a therapy derived from the square waveform ladder shaped Through the square wave pattern it is able to work directly on muscle motor neurons This therapy has low frequency and in conjunction with the square wave pattern allows direct work on muscle groupings How EMS works EMS sends comfortable impulses through the skin that stimulates the nerves in the treatment area When the ...

Page 5: ...trical n If your pain does not improve becomes seriously chronic or severe or continues for more than five days stop using the device and consult with your physician n The mere existence of pain functions as a very important warning telling us that something is wrong Therefore if you suffer from any serious illness consult your physician in order to confirm that it is advisable for you to use this...

Page 6: ...may not be effective CAUTION WHILE USING THE ELECTRODE DEVICE n If the device is not functioning properly or you feel discomfort immediately stop using the device n DO NOT use for any other purpose except for what it is intended for n DO NOT use the device while wearing other electronic devices such as watches as this may damage the device n Dispose of the device batteries and components according...

Page 7: ...ed n Use this device only with the electrode pads remote and lead wires recommended by the manufacturer n DO NOT use the product if it is closer than 12 inches 30 5cm to wireless communication equipment such as wireless home network routers cell phones cordless phones and their base stations and walkie talkies The electromagnetic interference of this wireless communication equipment may prevent th...

Page 8: ...Features n Channels Two channels n Treatment modes TENS 6 programs EMS 5 programs MASSAGE 3 programs n Output Amplitude 0 45V 500Ω Load n Waveform type Symmetrical Biphasic square pulse n Remote control Rear panel Dual 3 in 1 Electrotherapy Pain Relief User Manual Model ACRL 9100 Top View Output socket Battery cover ACRL3100_Manual_03 indd 14 15 10 31 18 4 41 PM ...

Page 9: ...button Mode select TENS EMS MASSAGE Treatment program select Neck Shoulder Arm LBack Joint Leg Tap Knead Rub Treatment mode Treatment time icon Treatment time display Treatment programs Lock icon Low battery icon Intensity icon LCD DISPLAY ACRL3100_Manual_03 indd 16 17 10 31 18 4 41 PM ...

Page 10: ... battery depends on the number of recharging rundown cycles it undergoes and how these cycles are performed n Whenever the device is not used frequently we recommend recharging the battery once a month STEP 1 Take the pads out of the sealed package attach pads to the lead wire Lead wire snaps onto the connector in the middle of the electrode pad STEP 2 Insert lead wire into the TENS unit Hold the ...

Page 11: ...nes recommended for this device by the manufacturer WARNING Make sure the device is turned off before applying or removing electrodes WARNING Place the electrode pads according to the Electrode Pad Placement Illustrations on pages 21 22 Pad Placement Illustrations Position of the electrodes TENS programs NECK CERVICAL PAIN Attach both pads on the neck DO NOT place on the carotid artery or throat o...

Page 12: ... between treatment modes TENS EMS Massage Press the Program button to select treatment part or Massage type ANKLE FOOT PAIN Attach pads per the illustration on the left for pain on the outside of your ankle foot Attach the pads per the illustration on the right for pain on the inside of your ankle foot DO NOT place electrode pads simultaneously to both feet CALF PAIN Attach both pads on the calf l...

Page 13: ...1 Turn unit off 2 Clean the device after use with a soft slightly moistened cloth and wipe gently Use only water and a mild soap if needed n DO NOT use chemicals like thinner benzene n DO NOT let water get into the internal area NOTE This device and accessories do not require sterilization Cleaning the electrode pads 1 Turn the power off 2 Remove pads from device 3 Wash the pads with water only wh...

Page 14: ... in a dry place n KEEP DEVICE AND ALL ACCESSORIES OUT OF REACH OF CHILDREN CAUTION When remote is not in use for a long period remove the batteries before storage to avoid liquid discharge from batteries n Power Source 3 0V DC 2x AAA Batteries n Frequency 2Hz 150Hz n Pulse Width 30us 350us n Wave form Biphasic square wave n Output Voltage 0 45V at 500 ohm load n Output Intensity Level 0 25 levels ...

Page 15: ...HOW TO CONTROL AND REDUCE YOUR PAIN Recommended treatment session as follows You may use the device for 30 minutes per session You may need to use it for longer maximum 3 times per day and maximum 90 minutes in total depending on the level of your pain CAUTION When to stop using the device n If you experienced an adverse reaction skin irritation redness burns headache or other painful sensation or...

Page 16: ...SIBLE CAUSES POSSIBLE SOLUTION Stimulation is ineffective Improper electrode pad placement Reposition electrode Unknown Contact clinician The skin becomes red and or you feel a stabbing pain Using electrodes on the same site every time Reposition the electrodes If at any time you feel pain or discomfort stop use immediately Electrodes do not adhere to the skin properly Ensure the electrodes are se...

Page 17: ...ransmitters or that use RF electromagnetic energy must have a label with this symbol IP22 SN IMPORTANT INFORMATION REGARDING ELECTROMAGNETIC COMPATIBILITY EMC CAUTION 1 This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided and this unit can be affected by portable and mobile RF communications equipment 2 Do not...

Page 18: ...cluding domestic establishments and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes Harmonic emissions lEC 61000 3 2 Not Applicable Voltage fluctuations flicker emissions lEC 61000 3 3 Not Applicable Electrical fast transient burst IEC 61000 4 4 Not Applicable Not Applicable Not Applicable Surge IEC 61000 4 5 Not Applicable...

Page 19: ...guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electrom...

Page 20: ...period for the device is one year from date of purchase In case of a warranty claim the date of purchase has to be proven by means of the sales receipt or invoice 2 Repairs under warranty do not extend the warranty period for the device or for the replacement parts 3 The following is excluded under the warranty n All damage due to improper treatment e g nonobservance of the user instruction n All ...

Page 21: ...Manufactured for Compass Health Brands Corp Middleburg Heights OH 44130 customerservice carex com 800 526 8051 Made in China 42 ACRL3100_02 2018 ACRL3100_Manual_03 indd 40 10 31 18 4 41 PM ...

Reviews: